Energy Performance Certificate

Flat 2, 12 Throwley Way, SM1 4AF

EPC Report

Energy rating

Current: 74 C | Potential: 74 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 74 C Current: 74 C 74 C Potential: 74 C

Environmental impact (CO₂)

Current: 74 | Potential: 74
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 74 Current: 74 74 Potential: 74
Field Value
LMK KEY 8328-7530-6829-5009-9902
ADDRESS1 Flat 2
ADDRESS2 12 Throwley Way
ADDRESS3
POSTCODE SM1 4AF
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 74
POTENTIAL ENERGY EFFICIENCY 74
PROPERTY TYPE Flat
BUILT FORM Detached
INSPECTION DATE 2018-10-01
LOCAL AUTHORITY E09000029
CONSTITUENCY E14001534
COUNTY
LODGEMENT DATE 2018-10-01
TRANSACTION TYPE New dwelling
ENVIRONMENT IMPACT CURRENT 74
ENVIRONMENT IMPACT POTENTIAL 74
ENERGY CONSUMPTION CURRENT 181
ENERGY CONSUMPTION POTENTIAL 181
CO2 EMISSIONS CURRENT 1.7
CO2 EMISS CURR PER FLOOR AREA 32
CO2 EMISSIONS POTENTIAL 1.7
LIGHTING COST CURRENT 41
LIGHTING COST POTENTIAL 41
HEATING COST CURRENT 260
HEATING COST POTENTIAL 260
HOT WATER COST CURRENT 96
HOT WATER COST POTENTIAL 96
TOTAL FLOOR AREA 52
ENERGY TARIFF standard tariff
MAINS GAS FLAG
FLOOR LEVEL 3
FLAT TOP STOREY Y
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Charging system linked to use of community heating, programmer and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT
NUMBER HABITABLE ROOMS
NUMBER HEATED ROOMS
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Community scheme
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Average thermal transmittance 0.34 W/m²K
FLOOR ENERGY EFF Average
FLOOR ENV EFF Average
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Average thermal transmittance 0.40 W/m²K
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Average thermal transmittance 0.20 W/m²K
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Community scheme
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Charging system linked to use of community heating, programmer and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.7
PHOTO SUPPLY
SOLAR WATER HEATING FLAG
MECHANICAL VENTILATION
ADDRESS Flat 2, 12 Throwley Way
LOCAL AUTHORITY LABEL Sutton
CONSTITUENCY LABEL Sutton and Cheam
POSTTOWN SUTTON
CONSTRUCTION AGE BAND 2018
LODGEMENT DATETIME 2018-10-01 13:38:57
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 8
LOW ENERGY FIXED LIGHT COUNT 8
UPRN 5870128125
UPRN SOURCE Energy Assessor
REPORT TYPE 3
Source file certificates-2018.csv
COUNTRY England
REGION E12000007
Address display