Energy Performance Certificate

Flat 1, 1 Pinder View, LS12 5LF

EPC Report

Energy rating

Current: 36 F | Potential: 81 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 36 F Current: 36 F 81 B Potential: 81 B

Environmental impact (CO₂)

Current: 43 | Potential: 68
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 43 Current: 43 68 Potential: 68
Field Value
LMK KEY 8327-7822-1719-9791-8902
ADDRESS1 Flat 1
ADDRESS2 1 Pinder View
ADDRESS3
POSTCODE LS12 5LF
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 36
POTENTIAL ENERGY EFFICIENCY 81
PROPERTY TYPE Flat
BUILT FORM Enclosed End-Terrace
INSPECTION DATE 2013-12-09
LOCAL AUTHORITY E08000035
CONSTITUENCY E14001324
COUNTY
LODGEMENT DATE 2013-12-24
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 43
ENVIRONMENT IMPACT POTENTIAL 68
ENERGY CONSUMPTION CURRENT 541
ENERGY CONSUMPTION POTENTIAL 286
CO2 EMISSIONS CURRENT 3.8
CO2 EMISS CURR PER FLOOR AREA 96
CO2 EMISSIONS POTENTIAL 2.0
LIGHTING COST CURRENT 43
LIGHTING COST POTENTIAL 28
HEATING COST CURRENT 538
HEATING COST POTENTIAL 154
HOT WATER COST CURRENT 407
HOT WATER COST POTENTIAL 100
TOTAL FLOOR AREA 39
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL 0
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Appliance thermostats
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 2
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 33
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, standard tariff
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Very Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION (another dwelling above)
ROOF ENERGY EFF N/A
ROOF ENV EFF N/A
MAINHEAT DESCRIPTION Room heaters, electric
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Appliance thermostats
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 33% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH 2.05
FLOOR HEIGHT 1.96
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS Flat 1, 1 Pinder View
LOCAL AUTHORITY LABEL Leeds
CONSTITUENCY LABEL Leeds South West and Morley
POSTTOWN LEEDS
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2013-12-24 20:24:07
TENURE Rented (private)
FIXED LIGHTING OUTLETS COUNT 6
LOW ENERGY FIXED LIGHT COUNT 2
UPRN 72686732
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2013.csv
COUNTRY England
REGION E12000003
Address display
Nation ew