Energy Performance Certificate

4, The Warren, AL5 2NH

EPC Report

Energy rating

Current: 39 E | Potential: 73 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 39 E Current: 39 E 73 C Potential: 73 C

Environmental impact (CO₂)

Current: 31 | Potential: 64
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 31 Current: 31 64 Potential: 64
Field Value
LMK KEY 8318-7629-5900-7545-9906
ADDRESS1 4, The Warren
ADDRESS2
ADDRESS3
POSTCODE AL5 2NH
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 39
POTENTIAL ENERGY EFFICIENCY 73
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2018-01-05
LOCAL AUTHORITY E07000240
CONSTITUENCY E14001268
COUNTY
LODGEMENT DATE 2018-01-07
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 31
ENVIRONMENT IMPACT POTENTIAL 64
ENERGY CONSUMPTION CURRENT 382
ENERGY CONSUMPTION POTENTIAL 161
CO2 EMISSIONS CURRENT 17
CO2 EMISS CURR PER FLOOR AREA 70
CO2 EMISSIONS POTENTIAL 7.5
LIGHTING COST CURRENT 199
LIGHTING COST POTENTIAL 111
HEATING COST CURRENT 2882
HEATING COST POTENTIAL 1494
HOT WATER COST CURRENT 357
HOT WATER COST POTENTIAL 127
TOTAL FLOOR AREA 250
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 25
GLAZED TYPE double glazing installed before 2002
GLAZED AREA Normal
EXTENSION COUNT 2
NUMBER HABITABLE ROOMS 10
NUMBER HEATED ROOMS 10
LOW ENERGY LIGHTING 18
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION From main system, no cylinder thermostat
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Some double glazing
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION Room heaters, dual fuel (mineral and wood)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 18% of fixed outlets
LIGHTING ENERGY EFF Poor
LIGHTING ENV EFF Poor
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.59
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 4, The Warren
LOCAL AUTHORITY LABEL St Albans
CONSTITUENCY LABEL Harpenden and Berkhamsted
POSTTOWN HARPENDEN
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2018-01-07 08:34:36
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 22
LOW ENERGY FIXED LIGHT COUNT 4
UPRN 100080837400
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2018.csv
COUNTRY England
REGION E12000006
Address display
Nation ew