Energy Performance Certificate

59, Main Road, Bolton le Sands, LA5 8DL

EPC Report

Energy rating

Current: 46 E | Potential: 71 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 46 E Current: 46 E 71 C Potential: 71 C

Environmental impact (CO₂)

Current: 41 | Potential: 66
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 41 Current: 41 66 Potential: 66
Field Value
LMK KEY 8317-7527-0670-8605-0926
ADDRESS1 59, Main Road
ADDRESS2 Bolton le Sands
ADDRESS3
POSTCODE LA5 8DL
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 46
POTENTIAL ENERGY EFFICIENCY 71
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2013-03-25
LOCAL AUTHORITY E07000121
CONSTITUENCY E14001372
COUNTY
LODGEMENT DATE 2013-03-26
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 41
ENVIRONMENT IMPACT POTENTIAL 66
ENERGY CONSUMPTION CURRENT 329
ENERGY CONSUMPTION POTENTIAL 174
CO2 EMISSIONS CURRENT 7.4
CO2 EMISS CURR PER FLOOR AREA 63
CO2 EMISSIONS POTENTIAL 4.0
LIGHTING COST CURRENT 111
LIGHTING COST POTENTIAL 59
HEATING COST CURRENT 1257
HEATING COST POTENTIAL 842
HOT WATER COST CURRENT 93
HOT WATER COST POTENTIAL 93
TOTAL FLOOR AREA 117
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, TRVs and bypass
MULTI GLAZE PROPORTION 10
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 11
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Some double glazing
WINDOWS ENERGY EFF Very Poor
WINDOWS ENV EFF Very Poor
WALLS DESCRIPTION Sandstone, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, TRVs and bypass
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 11% of fixed outlets
LIGHTING ENERGY EFF Poor
LIGHTING ENV EFF Poor
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.6
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 59, Main Road, Bolton le Sands
LOCAL AUTHORITY LABEL Lancaster
CONSTITUENCY LABEL Morecambe and Lunesdale
POSTTOWN CARNFORTH
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2013-03-26 15:13:29
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 18
LOW ENERGY FIXED LIGHT COUNT 2
UPRN 100010456375
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2013.csv
COUNTRY England
REGION E12000002
Address display