Energy Performance Certificate

23, Belham Road, PE1 3HS

EPC Report

Energy rating

Current: 45 E | Potential: 82 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 45 E Current: 45 E 82 B Potential: 82 B

Environmental impact (CO₂)

Current: 42 | Potential: 81
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 42 Current: 42 81 Potential: 81
Field Value
LMK KEY 8317-7027-0210-5697-7996
ADDRESS1 23, Belham Road
ADDRESS2
ADDRESS3
POSTCODE PE1 3HS
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 45
POTENTIAL ENERGY EFFICIENCY 82
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2013-03-13
LOCAL AUTHORITY E06000031
CONSTITUENCY E14001425
COUNTY
LODGEMENT DATE 2013-03-13
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 42
ENVIRONMENT IMPACT POTENTIAL 81
ENERGY CONSUMPTION CURRENT 372
ENERGY CONSUMPTION POTENTIAL 101
CO2 EMISSIONS CURRENT 5.5
CO2 EMISS CURR PER FLOOR AREA 72
CO2 EMISSIONS POTENTIAL 1.6
LIGHTING COST CURRENT 71
LIGHTING COST POTENTIAL 44
HEATING COST CURRENT 859
HEATING COST POTENTIAL 480
HOT WATER COST CURRENT 206
HOT WATER COST POTENTIAL 69
TOTAL FLOOR AREA 77
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, TRVs and bypass
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 40
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION From main system, no cylinder thermostat
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, dual fuel (mineral and wood)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, TRVs and bypass
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 40% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.6
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 23, Belham Road
LOCAL AUTHORITY LABEL Peterborough
CONSTITUENCY LABEL Peterborough
POSTTOWN PETERBOROUGH
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2013-03-13 11:43:01
TENURE Rented (private)
FIXED LIGHTING OUTLETS COUNT 10
LOW ENERGY FIXED LIGHT COUNT 4
UPRN 100090177366
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2013.csv
COUNTRY England
REGION E12000006
Address display
Nation ew