Energy Performance Certificate

Threshing Barn, Westerfield Road, Westerfield, IP6 9AA

EPC Report

Energy rating

Current: 86 B | Potential: 98 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 86 B Current: 86 B 98 A Potential: 98 A

Environmental impact (CO₂)

Current: 88 | Potential: 98
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 88 Current: 88 98 Potential: 98
Field Value
LMK KEY 8308-0875-1739-0107-0583
ADDRESS1 Threshing Barn
ADDRESS2 Westerfield Road
ADDRESS3 Westerfield
POSTCODE IP6 9AA
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING B
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 86
POTENTIAL ENERGY EFFICIENCY 98
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2018-05-03
LOCAL AUTHORITY E07000244
CONSTITUENCY E14001156
COUNTY
LODGEMENT DATE 2018-05-03
TRANSACTION TYPE New dwelling
ENVIRONMENT IMPACT CURRENT 88
ENVIRONMENT IMPACT POTENTIAL 98
ENERGY CONSUMPTION CURRENT 59
ENERGY CONSUMPTION POTENTIAL 5
CO2 EMISSIONS CURRENT 3.1
CO2 EMISS CURR PER FLOOR AREA 10
CO2 EMISSIONS POTENTIAL 0.3
LIGHTING COST CURRENT 119
LIGHTING COST POTENTIAL 119
HEATING COST CURRENT 656
HEATING COST POTENTIAL 656
HOT WATER COST CURRENT 194
HOT WATER COST POTENTIAL 194
TOTAL FLOOR AREA 313
ENERGY TARIFF standard tariff
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Time and temperature zone control
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT
NUMBER HABITABLE ROOMS
NUMBER HEATED ROOMS
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Average thermal transmittance 0.16 W/m²K
FLOOR ENERGY EFF Very Good
FLOOR ENV EFF Very Good
WINDOWS DESCRIPTION High performance glazing
WINDOWS ENERGY EFF Very Good
WINDOWS ENV EFF Very Good
WALLS DESCRIPTION Average thermal transmittance 0.24 W/m²K
WALLS ENERGY EFF Very Good
WALLS ENV EFF Very Good
SECONDHEAT DESCRIPTION Room heaters, wood logs
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Average thermal transmittance 0.11 W/m²K
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Ground source heat pump, underfloor, electric
MAINHEAT ENERGY EFF Very Good
MAINHEAT ENV EFF Very Good
MAINHEATCONT DESCRIPTION Time and temperature zone control
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL Electricity: electricity, unspecified tariff
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.69
PHOTO SUPPLY
SOLAR WATER HEATING FLAG
MECHANICAL VENTILATION
ADDRESS Threshing Barn, Westerfield Road, Westerfield
LOCAL AUTHORITY LABEL East Suffolk
CONSTITUENCY LABEL Central Suffolk and North Ipswich
POSTTOWN IPSWICH
CONSTRUCTION AGE BAND 2016
LODGEMENT DATETIME 2018-05-03 15:03:40
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 24
LOW ENERGY FIXED LIGHT COUNT 24
UPRN 10093543998
UPRN SOURCE Energy Assessor
REPORT TYPE 3
Source file certificates-2018.csv
COUNTRY England
REGION E12000006
Address display