Energy Performance Certificate

14, Bowdens Close, Bovey Tracey, TQ13 9GT

EPC Report

Energy rating

Current: 75 C | Potential: 90 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 75 C Current: 75 C 90 B Potential: 90 B

Environmental impact (CO₂)

Current: 77 | Potential: 92
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 77 Current: 77 92 Potential: 92
Field Value
LMK KEY 8307-7320-1909-0511-2996
ADDRESS1 14, Bowdens Close
ADDRESS2 Bovey Tracey
ADDRESS3
POSTCODE TQ13 9GT
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 75
POTENTIAL ENERGY EFFICIENCY 90
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2013-10-19
LOCAL AUTHORITY E07000045
CONSTITUENCY E14001155
COUNTY
LODGEMENT DATE 2013-10-19
TRANSACTION TYPE FiT application
ENVIRONMENT IMPACT CURRENT 77
ENVIRONMENT IMPACT POTENTIAL 92
ENERGY CONSUMPTION CURRENT 138
ENERGY CONSUMPTION POTENTIAL 28
CO2 EMISSIONS CURRENT 1.8
CO2 EMISS CURR PER FLOOR AREA 26
CO2 EMISSIONS POTENTIAL 0.4
LIGHTING COST CURRENT 68
LIGHTING COST POTENTIAL 44
HEATING COST CURRENT 299
HEATING COST POTENTIAL 304
HOT WATER COST CURRENT 103
HOT WATER COST POTENTIAL 67
TOTAL FLOOR AREA 67
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 46
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, insulated (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 46% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.4
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 14, Bowdens Close, Bovey Tracey
LOCAL AUTHORITY LABEL Teignbridge
CONSTITUENCY LABEL Central Devon
POSTTOWN NEWTON ABBOT
CONSTRUCTION AGE BAND England and Wales: 2003-2006
LODGEMENT DATETIME 2013-10-19 12:38:22
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 13
LOW ENERGY FIXED LIGHT COUNT 6
UPRN 10032971226
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2013.csv
COUNTRY England
REGION E12000009
Address display
Nation ew