Energy Performance Certificate

59, Bailey Avenue, Hockley, B77 5ND

EPC Report

Energy rating

Current: 51 E | Potential: 92 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 51 E Current: 51 E 92 A Potential: 92 A

Environmental impact (CO₂)

Current: 47 | Potential: 95
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 47 Current: 47 95 Potential: 95
Field Value
LMK KEY 8306-8653-8729-5097-7353
ADDRESS1 59, Bailey Avenue
ADDRESS2 Hockley
ADDRESS3
POSTCODE B77 5ND
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 51
POTENTIAL ENERGY EFFICIENCY 92
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2015-07-15
LOCAL AUTHORITY E07000199
CONSTITUENCY E14001538
COUNTY
LODGEMENT DATE 2015-07-16
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 47
ENVIRONMENT IMPACT POTENTIAL 95
ENERGY CONSUMPTION CURRENT 586
ENERGY CONSUMPTION POTENTIAL 41
CO2 EMISSIONS CURRENT 3.0
CO2 EMISS CURR PER FLOOR AREA 104
CO2 EMISSIONS POTENTIAL 0.2
LIGHTING COST CURRENT 22
LIGHTING COST POTENTIAL 22
HEATING COST CURRENT 429
HEATING COST POTENTIAL 270
HOT WATER COST CURRENT 255
HOT WATER COST POTENTIAL 59
TOTAL FLOOR AREA 29
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 70
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system, no cylinder thermostat
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Partial double glazing
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.4
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 59, Bailey Avenue, Hockley
LOCAL AUTHORITY LABEL Tamworth
CONSTITUENCY LABEL Tamworth
POSTTOWN TAMWORTH
CONSTRUCTION AGE BAND England and Wales: 1930-1949
LODGEMENT DATETIME 2015-07-16 18:58:40
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 9
LOW ENERGY FIXED LIGHT COUNT 9
UPRN 394001498
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2015.csv
COUNTRY England
REGION E12000005
Address display
Nation ew