Energy Performance Certificate

18, Monsell Drive, LE2 8PN

EPC Report

Energy rating

Current: 41 E | Potential: 68 D
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 41 E Current: 41 E 68 D Potential: 68 D

Environmental impact (CO₂)

Current: 33 | Potential: 59
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 33 Current: 33 59 Potential: 59
Field Value
LMK KEY 8305-7329-4029-9004-5902
ADDRESS1 18, Monsell Drive
ADDRESS2
ADDRESS3
POSTCODE LE2 8PN
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING D
CURRENT ENERGY EFFICIENCY 41
POTENTIAL ENERGY EFFICIENCY 68
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2015-11-04
LOCAL AUTHORITY E06000016
CONSTITUENCY E14001328
COUNTY
LODGEMENT DATE 2015-11-04
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 33
ENVIRONMENT IMPACT POTENTIAL 59
ENERGY CONSUMPTION CURRENT 392
ENERGY CONSUMPTION POTENTIAL 204
CO2 EMISSIONS CURRENT 11
CO2 EMISS CURR PER FLOOR AREA 72
CO2 EMISSIONS POTENTIAL 6.0
LIGHTING COST CURRENT 90
LIGHTING COST POTENTIAL 90
HEATING COST CURRENT 2059
HEATING COST POTENTIAL 1323
HOT WATER COST CURRENT 205
HOT WATER COST POTENTIAL 81
TOTAL FLOOR AREA 158
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 96
GLAZED TYPE double glazing installed before 2002
GLAZED AREA Normal
EXTENSION COUNT 3
NUMBER HABITABLE ROOMS 7
NUMBER HEATED ROOMS 7
LOW ENERGY LIGHTING 89
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Mostly double glazing
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, dual fuel (mineral and wood)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 89% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.69
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 18, Monsell Drive
LOCAL AUTHORITY LABEL Leicester
CONSTITUENCY LABEL Leicester West
POSTTOWN LEICESTER
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2015-11-04 23:58:02
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 18
LOW ENERGY FIXED LIGHT COUNT 16
UPRN 2465029070
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2015.csv
COUNTRY England
REGION E12000004
Address display
Nation ew