Energy Performance Certificate

2, Laxton Gardens, Merstham, RH1 3NJ

EPC Report

Energy rating

Current: 54 E | Potential: 69 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 54 E Current: 54 E 69 C Potential: 69 C

Environmental impact (CO₂)

Current: 68 | Potential: 80
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 68 Current: 68 80 Potential: 80
Field Value
LMK KEY 8304-9503-0929-9177-5153
ADDRESS1 2, Laxton Gardens
ADDRESS2 Merstham
ADDRESS3
POSTCODE RH1 3NJ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 54
POTENTIAL ENERGY EFFICIENCY 69
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2015-09-30
LOCAL AUTHORITY E07000211
CONSTITUENCY E14001215
COUNTY
LODGEMENT DATE 2015-10-06
TRANSACTION TYPE FiT application
ENVIRONMENT IMPACT CURRENT 68
ENVIRONMENT IMPACT POTENTIAL 80
ENERGY CONSUMPTION CURRENT 152
ENERGY CONSUMPTION POTENTIAL 75
CO2 EMISSIONS CURRENT 3.1
CO2 EMISS CURR PER FLOOR AREA 32
CO2 EMISSIONS POTENTIAL 1.7
LIGHTING COST CURRENT 72
LIGHTING COST POTENTIAL 72
HEATING COST CURRENT 833
HEATING COST POTENTIAL 785
HOT WATER COST CURRENT 217
HOT WATER COST POTENTIAL 137
TOTAL FLOOR AREA 94
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 78
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, LPG
MAINHEAT ENERGY EFF Poor
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 78% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL LPG (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.4
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 2, Laxton Gardens, Merstham
LOCAL AUTHORITY LABEL Reigate and Banstead
CONSTITUENCY LABEL East Surrey
POSTTOWN REDHILL
CONSTRUCTION AGE BAND England and Wales: 1930-1949
LODGEMENT DATETIME 2015-10-06 00:09:10
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 9
LOW ENERGY FIXED LIGHT COUNT 7
UPRN 68150682
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2015.csv
COUNTRY England
REGION E12000008
Address display