Energy Performance Certificate

2, Ewan Close, SS9 3RB

EPC Report

Energy rating

Current: 74 C | Potential: 80 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 74 C Current: 74 C 80 C Potential: 80 C

Environmental impact (CO₂)

Current: 69 | Potential: 74
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 69 Current: 69 74 Potential: 74
Field Value
LMK KEY 8304-4934-2929-9896-1653
ADDRESS1 2, Ewan Close
ADDRESS2
ADDRESS3
POSTCODE SS9 3RB
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 74
POTENTIAL ENERGY EFFICIENCY 80
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2015-06-17
LOCAL AUTHORITY E07000069
CONSTITUENCY E14001154
COUNTY
LODGEMENT DATE 2015-06-17
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 69
ENVIRONMENT IMPACT POTENTIAL 74
ENERGY CONSUMPTION CURRENT 144
ENERGY CONSUMPTION POTENTIAL 115
CO2 EMISSIONS CURRENT 5.5
CO2 EMISS CURR PER FLOOR AREA 25
CO2 EMISSIONS POTENTIAL 4.4
LIGHTING COST CURRENT 124
LIGHTING COST POTENTIAL 95
HEATING COST CURRENT 938
HEATING COST POTENTIAL 942
HOT WATER COST CURRENT 163
HOT WATER COST POTENTIAL 163
TOTAL FLOOR AREA 217
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Time and temperature zone control
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 6
NUMBER HEATED ROOMS 6
LOW ENERGY LIGHTING 69
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Solid brick, with internal insulation
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 300 mm loft insulation
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Time and temperature zone control
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
LIGHTING DESCRIPTION Low energy lighting in 69% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.42
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 2, Ewan Close
LOCAL AUTHORITY LABEL Castle Point
CONSTITUENCY LABEL Castle Point
POSTTOWN LEIGH-ON-SEA
CONSTRUCTION AGE BAND England and Wales: 1930-1949
LODGEMENT DATETIME 2015-06-17 20:50:16
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 29
LOW ENERGY FIXED LIGHT COUNT 20
UPRN 100090357057
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2015.csv
COUNTRY England
REGION E12000006
Address display
Nation ew