Energy Performance Certificate

4 Weavers House, Mannheim Quay, Maritime Quarter, SA1 1RU

EPC Report

Energy rating

Current: 61 D | Potential: 79 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 61 D Current: 61 D 79 C Potential: 79 C

Environmental impact (CO₂)

Current: 55 | Potential: 65
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 55 Current: 55 65 Potential: 65
Field Value
LMK KEY 8302-2995-6129-6626-2813
ADDRESS1 4 Weavers House
ADDRESS2 Mannheim Quay
ADDRESS3 Maritime Quarter
POSTCODE SA1 1RU
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 61
POTENTIAL ENERGY EFFICIENCY 79
PROPERTY TYPE Flat
BUILT FORM Mid-Terrace
INSPECTION DATE 2019-08-21
LOCAL AUTHORITY W06000011
CONSTITUENCY W07000108
COUNTY
LODGEMENT DATE 2019-08-21
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 55
ENVIRONMENT IMPACT POTENTIAL 65
ENERGY CONSUMPTION CURRENT 378
ENERGY CONSUMPTION POTENTIAL 289
CO2 EMISSIONS CURRENT 2.5
CO2 EMISS CURR PER FLOOR AREA 64
CO2 EMISSIONS POTENTIAL 1.9
LIGHTING COST CURRENT 59
LIGHTING COST POTENTIAL 38
HEATING COST CURRENT 355
HEATING COST POTENTIAL 182
HOT WATER COST CURRENT 231
HOT WATER COST POTENTIAL 138
TOTAL FLOOR AREA 40
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL 1
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS No thermostatic control of room temperature
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 2
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 25
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION (another dwelling above)
ROOF ENERGY EFF N/A
ROOF ENV EFF N/A
MAINHEAT DESCRIPTION Room heaters, electric
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION No thermostatic control of room temperature
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 25% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR unheated corridor
UNHEATED CORRIDOR LENGTH 7.1
FLOOR HEIGHT 2.3
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 4 Weavers House, Mannheim Quay, Maritime Quarter
LOCAL AUTHORITY LABEL Swansea
CONSTITUENCY LABEL Swansea West
POSTTOWN SWANSEA
CONSTRUCTION AGE BAND England and Wales: 1983-1990
LODGEMENT DATETIME 2019-08-21 16:33:41
TENURE unknown
FIXED LIGHTING OUTLETS COUNT 8
LOW ENERGY FIXED LIGHT COUNT 2
UPRN 100100361807
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2019.csv
COUNTRY Wales
REGION W99999999
Address display
Nation ew