Energy Performance Certificate

16, The Boxhill, CV3 1ES

EPC Report

Energy rating

Current: 20 G | Potential: 58 D
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 20 G Current: 20 G 58 D Potential: 58 D

Environmental impact (CO₂)

Current: 25 | Potential: 55
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 25 Current: 25 55 Potential: 55
Field Value
LMK KEY 8302-0021-9329-4627-0873
ADDRESS1 16, The Boxhill
ADDRESS2
ADDRESS3
POSTCODE CV3 1ES
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING G
POTENTIAL ENERGY RATING D
CURRENT ENERGY EFFICIENCY 20
POTENTIAL ENERGY EFFICIENCY 58
PROPERTY TYPE Flat
BUILT FORM End-Terrace
INSPECTION DATE 2013-08-22
LOCAL AUTHORITY E08000026
CONSTITUENCY E14001182
COUNTY
LODGEMENT DATE 2013-08-22
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 25
ENVIRONMENT IMPACT POTENTIAL 55
ENERGY CONSUMPTION CURRENT 608
ENERGY CONSUMPTION POTENTIAL 282
CO2 EMISSIONS CURRENT 7.6
CO2 EMISS CURR PER FLOOR AREA 114
CO2 EMISSIONS POTENTIAL 3.6
LIGHTING COST CURRENT 52
LIGHTING COST POTENTIAL 53
HEATING COST CURRENT 1186
HEATING COST POTENTIAL 634
HOT WATER COST CURRENT 436
HOT WATER COST POTENTIAL 97
TOTAL FLOOR AREA 67
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL 3
FLAT TOP STOREY Y
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS No thermostatic control of room temperature
MULTI GLAZE PROPORTION 0
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 1
LOW ENERGY LIGHTING 71
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, standard tariff
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Very Poor
FLOOR DESCRIPTION (other premises below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Single glazed
WINDOWS ENERGY EFF Very Poor
WINDOWS ENV EFF Very Poor
WALLS DESCRIPTION System built, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Room heaters, mains gas
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION No thermostatic control of room temperature
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 71% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.45
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 16, The Boxhill
LOCAL AUTHORITY LABEL Coventry
CONSTITUENCY LABEL Coventry South
POSTTOWN COVENTRY
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2013-10-08 10:00:19
TENURE Rented (social)
FIXED LIGHTING OUTLETS COUNT 7
LOW ENERGY FIXED LIGHT COUNT 5
UPRN 100070709766
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2013.csv
COUNTRY England
REGION E12000005
Address display
Nation ew