Energy Performance Certificate

26, Sister Ann Way, RH19 3BQ

EPC Report

Energy rating

Current: 82 B | Potential: 93 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 82 B Current: 82 B 93 A Potential: 93 A

Environmental impact (CO₂)

Current: 84 | Potential: 95
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 84 Current: 84 95 Potential: 95
Field Value
LMK KEY 8301-8724-2139-9197-5963
ADDRESS1 26, Sister Ann Way
ADDRESS2
ADDRESS3
POSTCODE RH19 3BQ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING B
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 82
POTENTIAL ENERGY EFFICIENCY 93
PROPERTY TYPE House
BUILT FORM
INSPECTION DATE 2016-01-12
LOCAL AUTHORITY E07000228
CONSTITUENCY E14001212
COUNTY
LODGEMENT DATE 2016-01-12
TRANSACTION TYPE New dwelling
ENVIRONMENT IMPACT CURRENT 84
ENVIRONMENT IMPACT POTENTIAL 95
ENERGY CONSUMPTION CURRENT 96
ENERGY CONSUMPTION POTENTIAL 20
CO2 EMISSIONS CURRENT 1.6
CO2 EMISS CURR PER FLOOR AREA 17
CO2 EMISSIONS POTENTIAL 0.3
LIGHTING COST CURRENT 62
LIGHTING COST POTENTIAL 62
HEATING COST CURRENT 283
HEATING COST POTENTIAL 284
HOT WATER COST CURRENT 110
HOT WATER COST POTENTIAL 58
TOTAL FLOOR AREA 93
ENERGY TARIFF standard tariff
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Time and temperature zone control
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT
NUMBER HABITABLE ROOMS
NUMBER HEATED ROOMS
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Average thermal transmittance 0.18 W/m²K
FLOOR ENERGY EFF Very Good
FLOOR ENV EFF Very Good
WINDOWS DESCRIPTION High performance glazing
WINDOWS ENERGY EFF Very Good
WINDOWS ENV EFF Very Good
WALLS DESCRIPTION Average thermal transmittance 0.27 W/m²K
WALLS ENERGY EFF Very Good
WALLS ENV EFF Very Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Average thermal transmittance 0.11 W/m²K
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Time and temperature zone control
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL Gas: mains gas
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.294
PHOTO SUPPLY
SOLAR WATER HEATING FLAG
MECHANICAL VENTILATION
ADDRESS 26, Sister Ann Way
LOCAL AUTHORITY LABEL Mid Sussex
CONSTITUENCY LABEL East Grinstead and Uckfield
POSTTOWN EAST GRINSTEAD
CONSTRUCTION AGE BAND 2016
LODGEMENT DATETIME 2016-01-12 14:56:31
TENURE unknown
FIXED LIGHTING OUTLETS COUNT 12
LOW ENERGY FIXED LIGHT COUNT 12
UPRN 10090943990
UPRN SOURCE Energy Assessor
REPORT TYPE 3
Source file certificates-2016.csv
COUNTRY England
REGION E12000008
Address display
Nation ew