Energy Performance Certificate

31, Lower Road, Great Amwell, SG12 9SZ

EPC Report

Energy rating

Current: 78 C | Potential: 84 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 78 C Current: 78 C 84 B Potential: 84 B

Environmental impact (CO₂)

Current: 76 | Potential: 81
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 76 Current: 76 81 Potential: 81
Field Value
LMK KEY 8301-7392-4529-5007-8343
ADDRESS1 31, Lower Road
ADDRESS2 Great Amwell
ADDRESS3
POSTCODE SG12 9SZ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 78
POTENTIAL ENERGY EFFICIENCY 84
PROPERTY TYPE Bungalow
BUILT FORM Detached
INSPECTION DATE 2014-07-01
LOCAL AUTHORITY E07000242
CONSTITUENCY E14001139
COUNTY
LODGEMENT DATE 2014-07-07
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 76
ENVIRONMENT IMPACT POTENTIAL 81
ENERGY CONSUMPTION CURRENT 104
ENERGY CONSUMPTION POTENTIAL 78
CO2 EMISSIONS CURRENT 5.0
CO2 EMISS CURR PER FLOOR AREA 20
CO2 EMISSIONS POTENTIAL 3.8
LIGHTING COST CURRENT 186
LIGHTING COST POTENTIAL 102
HEATING COST CURRENT 874
HEATING COST POTENTIAL 889
HOT WATER COST CURRENT 130
HOT WATER COST POTENTIAL 130
TOTAL FLOOR AREA 252
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 9
NUMBER HEATED ROOMS 9
LOW ENERGY LIGHTING 17
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, insulated (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, dual fuel (mineral and wood)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Roof room(s), insulated (assumed)
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 17% of fixed outlets
LIGHTING ENERGY EFF Poor
LIGHTING ENV EFF Poor
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.6
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 31, Lower Road, Great Amwell
LOCAL AUTHORITY LABEL East Hertfordshire
CONSTITUENCY LABEL Broxbourne
POSTTOWN WARE
CONSTRUCTION AGE BAND England and Wales: 2007 onwards
LODGEMENT DATETIME 2014-07-07 11:07:04
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 35
LOW ENERGY FIXED LIGHT COUNT 6
UPRN 100080752557
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2014.csv
COUNTRY England
REGION E12000006
Address display
Nation ew