Energy Performance Certificate

162, Queens Park Road, BN2 0GG

EPC Report

Energy rating

Current: 69 C | Potential: 84 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 69 C Current: 69 C 84 B Potential: 84 B

Environmental impact (CO₂)

Current: 63 | Potential: 80
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 63 Current: 63 80 Potential: 80
Field Value
LMK KEY 8301-6422-5199-1992-4992
ADDRESS1 162, Queens Park Road
ADDRESS2
ADDRESS3
POSTCODE BN2 0GG
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 69
POTENTIAL ENERGY EFFICIENCY 84
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2019-12-12
LOCAL AUTHORITY E06000043
CONSTITUENCY E14001129
COUNTY
LODGEMENT DATE 2019-12-12
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 63
ENVIRONMENT IMPACT POTENTIAL 80
ENERGY CONSUMPTION CURRENT 186
ENERGY CONSUMPTION POTENTIAL 95
CO2 EMISSIONS CURRENT 5.7
CO2 EMISS CURR PER FLOOR AREA 33
CO2 EMISSIONS POTENTIAL 2.9
LIGHTING COST CURRENT 107
LIGHTING COST POTENTIAL 107
HEATING COST CURRENT 967
HEATING COST POTENTIAL 659
HOT WATER COST CURRENT 106
HOT WATER COST POTENTIAL 106
TOTAL FLOOR AREA 173
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 3
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 10
NUMBER HEATED ROOMS 10
LOW ENERGY LIGHTING 92
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 92% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.56
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 162, Queens Park Road
LOCAL AUTHORITY LABEL Brighton and Hove
CONSTITUENCY LABEL Brighton Kemptown and Peacehaven
POSTTOWN BRIGHTON
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2019-12-12 14:23:11
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 26
LOW ENERGY FIXED LIGHT COUNT 24
UPRN 22084742
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2019.csv
COUNTRY England
REGION E12000008
Address display
Nation ew