Energy Performance Certificate

The Annexe, Palace Lane, Beaulieu, SO42 7YG

EPC Report

Energy rating

Current: 20 G | Potential: 112 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 20 G Current: 20 G 112 A Potential: 112 A

Environmental impact (CO₂)

Current: 9 | Potential: 86
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 9 Current: 9 86 Potential: 86
Field Value
LMK KEY 8301-1423-7729-3797-6353
ADDRESS1 The Annexe
ADDRESS2 Palace Lane
ADDRESS3 Beaulieu
POSTCODE SO42 7YG
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING G
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 20
POTENTIAL ENERGY EFFICIENCY 112
PROPERTY TYPE Bungalow
BUILT FORM Detached
INSPECTION DATE 2015-07-12
LOCAL AUTHORITY E07000091
CONSTITUENCY E14001373
COUNTY
LODGEMENT DATE 2015-07-12
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 9
ENVIRONMENT IMPACT POTENTIAL 86
ENERGY CONSUMPTION CURRENT 988
ENERGY CONSUMPTION POTENTIAL 48
CO2 EMISSIONS CURRENT 9.5
CO2 EMISS CURR PER FLOOR AREA 167
CO2 EMISSIONS POTENTIAL 0.5
LIGHTING COST CURRENT 43
LIGHTING COST POTENTIAL 43
HEATING COST CURRENT 1380
HEATING COST POTENTIAL 424
HOT WATER COST CURRENT 222
HOT WATER COST POTENTIAL 78
TOTAL FLOOR AREA 57
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Automatic charge control
MULTI GLAZE PROPORTION 35
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 2
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Partial double glazing
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Timber frame, as built, partial insulation (assumed)
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Automatic charge control
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.1
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS The Annexe, Palace Lane, Beaulieu
LOCAL AUTHORITY LABEL New Forest
CONSTITUENCY LABEL New Forest East
POSTTOWN BROCKENHURST
CONSTRUCTION AGE BAND England and Wales: 1967-1975
LODGEMENT DATETIME 2015-07-12 10:17:38
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 5
LOW ENERGY FIXED LIGHT COUNT 5
UPRN 100062532254
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2015.csv
COUNTRY England
REGION E12000008
Address display
Nation ew