Energy Performance Certificate

Pine View, Towpath, TW17 9LL

EPC Report

Energy rating

Current: 21 F | Potential: 62 D
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 21 F Current: 21 F 62 D Potential: 62 D

Environmental impact (CO₂)

Current: 12 | Potential: 40
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 12 Current: 12 40 Potential: 40
Field Value
LMK KEY 8300-5946-4822-5707-8203
ADDRESS1 Pine View
ADDRESS2 Towpath
ADDRESS3
POSTCODE TW17 9LL
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING D
CURRENT ENERGY EFFICIENCY 21
POTENTIAL ENERGY EFFICIENCY 62
PROPERTY TYPE Bungalow
BUILT FORM Detached
INSPECTION DATE 2020-02-04
LOCAL AUTHORITY E07000213
CONSTITUENCY E14001505
COUNTY
LODGEMENT DATE 2020-02-06
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 12
ENVIRONMENT IMPACT POTENTIAL 40
ENERGY CONSUMPTION CURRENT 779
ENERGY CONSUMPTION POTENTIAL 385
CO2 EMISSIONS CURRENT 10
CO2 EMISS CURR PER FLOOR AREA 132
CO2 EMISSIONS POTENTIAL 5.0
LIGHTING COST CURRENT 131
LIGHTING COST POTENTIAL 68
HEATING COST CURRENT 1840
HEATING COST POTENTIAL 1123
HOT WATER COST CURRENT 363
HOT WATER COST POTENTIAL 113
TOTAL FLOOR AREA 77
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 36
GLAZED TYPE double glazing installed before 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 7
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Partial double glazing
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Timber frame, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 200 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Electric storage heaters, Room heaters, electric
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 7% of fixed outlets
LIGHTING ENERGY EFF Very Poor
LIGHTING ENV EFF Very Poor
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.48
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS Pine View, Towpath
LOCAL AUTHORITY LABEL Spelthorne
CONSTITUENCY LABEL Spelthorne
POSTTOWN SHEPPERTON
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2020-02-06 15:39:58
TENURE unknown
FIXED LIGHTING OUTLETS COUNT 14
LOW ENERGY FIXED LIGHT COUNT 1
UPRN 33035345
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2020.csv
COUNTRY England
REGION E12000008
Address display
Nation ew