Energy Performance Certificate

FLAT B, 4 ALEXANDRA ROAD, SKEGNESS, PE25 3RE

EPC Report

Energy rating

Current: 48 E | Potential: 76 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 48 E Current: 48 E 76 C Potential: 76 C

Environmental impact (CO₂)

Current: 45 | Potential: 61
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 45 Current: 45 61 Potential: 61
Field Value
LMK KEY 8300-3247-0122-2092-1493
ADDRESS1 FLAT B
ADDRESS2 4 ALEXANDRA ROAD
ADDRESS3 SKEGNESS
POSTCODE PE25 3RE
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 48
POTENTIAL ENERGY EFFICIENCY 76
PROPERTY TYPE Flat
BUILT FORM End-Terrace
INSPECTION DATE 2021-04-14
LOCAL AUTHORITY E07000137
CONSTITUENCY E14001114
COUNTY
LODGEMENT DATE 2021-04-15
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 45
ENVIRONMENT IMPACT POTENTIAL 61
ENERGY CONSUMPTION CURRENT 508
ENERGY CONSUMPTION POTENTIAL 343
CO2 EMISSIONS CURRENT 3.6
CO2 EMISS CURR PER FLOOR AREA 86
CO2 EMISSIONS POTENTIAL 2.5
LIGHTING COST CURRENT 43
LIGHTING COST POTENTIAL 50
HEATING COST CURRENT 783
HEATING COST POTENTIAL 288
HOT WATER COST CURRENT 181
HOT WATER COST POTENTIAL 158
TOTAL FLOOR AREA 42
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL 1
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Appliance thermostats
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 2
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 80
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Room heaters, electric
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION Appliance thermostats
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 80% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR no corridor
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.38
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS FLAT B, 4 ALEXANDRA ROAD, SKEGNESS
LOCAL AUTHORITY LABEL East Lindsey
CONSTITUENCY LABEL Boston and Skegness
POSTTOWN SKEGNESS
CONSTRUCTION AGE BAND England and Wales: 1930-1949
LODGEMENT DATETIME 2021-04-15 06:47:32
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 5
LOW ENERGY FIXED LIGHT COUNT 4
UPRN 100032172899
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2021.csv
COUNTRY England
REGION E12000004
Address display
Nation ew