Energy Performance Certificate

59, Adams Drive, Spittal, TD15 2JQ

EPC Report

Energy rating

Current: 63 D | Potential: 72 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 63 D Current: 63 D 72 C Potential: 72 C

Environmental impact (CO₂)

Current: 64 | Potential: 76
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 64 Current: 64 76 Potential: 76
Field Value
LMK KEY 8296-6629-5259-3851-2906
ADDRESS1 59, Adams Drive
ADDRESS2 Spittal
ADDRESS3
POSTCODE TD15 2JQ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 63
POTENTIAL ENERGY EFFICIENCY 72
PROPERTY TYPE Maisonette
BUILT FORM Semi-Detached
INSPECTION DATE 2016-11-09
LOCAL AUTHORITY E06000057
CONSTITUENCY E14001397
COUNTY
LODGEMENT DATE 2016-11-22
TRANSACTION TYPE ECO assessment
ENVIRONMENT IMPACT CURRENT 64
ENVIRONMENT IMPACT POTENTIAL 76
ENERGY CONSUMPTION CURRENT 337
ENERGY CONSUMPTION POTENTIAL 225
CO2 EMISSIONS CURRENT 2.4
CO2 EMISS CURR PER FLOOR AREA 59
CO2 EMISSIONS POTENTIAL 1.6
LIGHTING COST CURRENT 36
LIGHTING COST POTENTIAL 36
HEATING COST CURRENT 511
HEATING COST POTENTIAL 337
HOT WATER COST CURRENT 78
HOT WATER COST POTENTIAL 78
TOTAL FLOOR AREA 41
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL 1
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 2
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 80
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION (another dwelling above)
ROOF ENERGY EFF N/A
ROOF ENV EFF N/A
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 80% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR no corridor
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.4
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 59, Adams Drive, Spittal
LOCAL AUTHORITY LABEL Northumberland
CONSTITUENCY LABEL North Northumberland
POSTTOWN BERWICK-UPON-TWEED
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2016-11-22 16:16:17
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 5
LOW ENERGY FIXED LIGHT COUNT 4
UPRN 100110578354
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2016.csv
COUNTRY England
REGION E12000001
Address display
Nation ew