Energy Performance Certificate

5, Solomons Passage, SE15 3UH

EPC Report

Energy rating

Current: 71 C | Potential: 77 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 71 C Current: 71 C 77 C Potential: 77 C

Environmental impact (CO₂)

Current: 68 | Potential: 77
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 68 Current: 68 77 Potential: 77
Field Value
LMK KEY 8293-7422-5749-8596-1902
ADDRESS1 5, Solomons Passage
ADDRESS2
ADDRESS3
POSTCODE SE15 3UH
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 71
POTENTIAL ENERGY EFFICIENCY 77
PROPERTY TYPE Maisonette
BUILT FORM End-Terrace
INSPECTION DATE 2017-12-06
LOCAL AUTHORITY E09000028
CONSTITUENCY E14001333
COUNTY
LODGEMENT DATE 2017-12-07
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 68
ENVIRONMENT IMPACT POTENTIAL 77
ENERGY CONSUMPTION CURRENT 176
ENERGY CONSUMPTION POTENTIAL 125
CO2 EMISSIONS CURRENT 2.8
CO2 EMISS CURR PER FLOOR AREA 31
CO2 EMISSIONS POTENTIAL 2.0
LIGHTING COST CURRENT 75
LIGHTING COST POTENTIAL 76
HEATING COST CURRENT 386
HEATING COST POTENTIAL 295
HOT WATER COST CURRENT 194
HOT WATER COST POTENTIAL 129
TOTAL FLOOR AREA 90
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL 1
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Room thermostat only
MULTI GLAZE PROPORTION 50
GLAZED TYPE secondary glazing
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 80
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Partial secondary glazing
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION (another dwelling above)
ROOF ENERGY EFF N/A
ROOF ENV EFF N/A
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Room thermostat only
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 80% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR no corridor
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.326
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 5, Solomons Passage
LOCAL AUTHORITY LABEL Southwark
CONSTITUENCY LABEL Lewisham West and East Dulwich
POSTTOWN LONDON
CONSTRUCTION AGE BAND England and Wales: 1976-1982
LODGEMENT DATETIME 2017-12-07 14:52:37
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 10
LOW ENERGY FIXED LIGHT COUNT 8
UPRN 200003388719
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2017.csv
COUNTRY England
REGION E12000007
Address display
Nation ew