Energy Performance Certificate

15, Halifield Drive, DA17 5RS

EPC Report

Energy rating

Current: 66 D | Potential: 84 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 66 D Current: 66 D 84 B Potential: 84 B

Environmental impact (CO₂)

Current: 61 | Potential: 82
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 61 Current: 61 82 Potential: 82
Field Value
LMK KEY 8291-4923-5029-5597-1243
ADDRESS1 15, Halifield Drive
ADDRESS2
ADDRESS3
POSTCODE DA17 5RS
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 66
POTENTIAL ENERGY EFFICIENCY 84
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2014-12-12
LOCAL AUTHORITY E09000004
CONSTITUENCY E14001229
COUNTY
LODGEMENT DATE 2014-12-12
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 61
ENVIRONMENT IMPACT POTENTIAL 82
ENERGY CONSUMPTION CURRENT 215
ENERGY CONSUMPTION POTENTIAL 88
CO2 EMISSIONS CURRENT 3.9
CO2 EMISS CURR PER FLOOR AREA 38
CO2 EMISSIONS POTENTIAL 1.6
LIGHTING COST CURRENT 103
LIGHTING COST POTENTIAL 60
HEATING COST CURRENT 666
HEATING COST POTENTIAL 495
HOT WATER COST CURRENT 118
HOT WATER COST POTENTIAL 72
TOTAL FLOOR AREA 104
ENERGY TARIFF Unknown
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed before 2002
GLAZED AREA More Than Typical
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 27
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 27% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.34
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 15, Halifield Drive
LOCAL AUTHORITY LABEL Bexley
CONSTITUENCY LABEL Erith and Thamesmead
POSTTOWN BELVEDERE
CONSTRUCTION AGE BAND England and Wales: 1983-1990
LODGEMENT DATETIME 2014-12-12 15:30:11
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 15
LOW ENERGY FIXED LIGHT COUNT 4
UPRN 100020190266
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2014.csv
COUNTRY England
REGION E12000007
Address display
Nation ew