Energy Performance Certificate

30, Brewer Street, ME14 1RY

EPC Report

Energy rating

Current: 30 F | Potential: 59 D
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 30 F Current: 30 F 59 D Potential: 59 D

Environmental impact (CO₂)

Current: 30 | Potential: 51
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 30 Current: 30 51 Potential: 51
Field Value
LMK KEY 8288-7829-2660-2942-6922
ADDRESS1 30, Brewer Street
ADDRESS2
ADDRESS3
POSTCODE ME14 1RY
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING D
CURRENT ENERGY EFFICIENCY 30
POTENTIAL ENERGY EFFICIENCY 59
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2018-01-22
LOCAL AUTHORITY E07000110
CONSTITUENCY E14001349
COUNTY
LODGEMENT DATE 2018-01-22
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 30
ENVIRONMENT IMPACT POTENTIAL 51
ENERGY CONSUMPTION CURRENT 441
ENERGY CONSUMPTION POTENTIAL 231
CO2 EMISSIONS CURRENT 7.0
CO2 EMISS CURR PER FLOOR AREA 89
CO2 EMISSIONS POTENTIAL 3.9
LIGHTING COST CURRENT 95
LIGHTING COST POTENTIAL 61
HEATING COST CURRENT 1258
HEATING COST POTENTIAL 945
HOT WATER COST CURRENT 300
HOT WATER COST POTENTIAL 151
TOTAL FLOOR AREA 79
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS No thermostatic control of room temperature
MULTI GLAZE PROPORTION 95
GLAZED TYPE double glazing installed before 2002
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 43
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Mostly double glazing
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Room heaters, dual fuel (mineral and wood)
MAINHEAT ENERGY EFF Poor
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION No thermostatic control of room temperature
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 43% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL dual fuel - mineral + wood
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.38
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 30, Brewer Street
LOCAL AUTHORITY LABEL Maidstone
CONSTITUENCY LABEL Maidstone and Malling
POSTTOWN MAIDSTONE
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2018-01-22 22:54:16
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 7
LOW ENERGY FIXED LIGHT COUNT 3
UPRN 200003697607
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2018.csv
COUNTRY England
REGION E12000008
Address display
Nation ew