Energy Performance Certificate

75, Tangmere Drive, CF5 2PQ

EPC Report

Energy rating

Current: 41 E | Potential: 93 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 41 E Current: 41 E 93 A Potential: 93 A

Environmental impact (CO₂)

Current: 48 | Potential: 77
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 48 Current: 48 77 Potential: 77
Field Value
LMK KEY 8288-6220-6709-8258-8992
ADDRESS1 75, Tangmere Drive
ADDRESS2
ADDRESS3
POSTCODE CF5 2PQ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 41
POTENTIAL ENERGY EFFICIENCY 93
PROPERTY TYPE House
BUILT FORM Enclosed End-Terrace
INSPECTION DATE 2018-10-18
LOCAL AUTHORITY W06000015
CONSTITUENCY W07000092
COUNTY
LODGEMENT DATE 2018-10-18
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 48
ENVIRONMENT IMPACT POTENTIAL 77
ENERGY CONSUMPTION CURRENT 465
ENERGY CONSUMPTION POTENTIAL 160
CO2 EMISSIONS CURRENT 3.1
CO2 EMISS CURR PER FLOOR AREA 79
CO2 EMISSIONS POTENTIAL 1.1
LIGHTING COST CURRENT 49
LIGHTING COST POTENTIAL 35
HEATING COST CURRENT 548
HEATING COST POTENTIAL 271
HOT WATER COST CURRENT 396
HOT WATER COST POTENTIAL 78
TOTAL FLOOR AREA 40
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS No thermostatic control of room temperature
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 2
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 44
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, standard tariff
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Timber frame, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 200 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Room heaters, electric
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION No thermostatic control of room temperature
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 44% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.29
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 75, Tangmere Drive
LOCAL AUTHORITY LABEL Cardiff
CONSTITUENCY LABEL Cardiff West
POSTTOWN CARDIFF
CONSTRUCTION AGE BAND England and Wales: 1976-1982
LODGEMENT DATETIME 2018-10-18 15:04:52
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 9
LOW ENERGY FIXED LIGHT COUNT 4
UPRN 100100089104
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2018.csv
COUNTRY Wales
REGION W99999999
Address display