Energy Performance Certificate

3, Chapel Green, Appleton Roebuck, YO23 7DR

EPC Report

Energy rating

Current: 50 E | Potential: 82 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 50 E Current: 50 E 82 B Potential: 82 B

Environmental impact (CO₂)

Current: 42 | Potential: 75
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 42 Current: 42 75 Potential: 75
Field Value
LMK KEY 8286-7022-1330-2287-7922
ADDRESS1 3, Chapel Green
ADDRESS2 Appleton Roebuck
ADDRESS3
POSTCODE YO23 7DR
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 50
POTENTIAL ENERGY EFFICIENCY 82
PROPERTY TYPE House
BUILT FORM End-Terrace
INSPECTION DATE 2016-02-23
LOCAL AUTHORITY E06000065
CONSTITUENCY E14001582
COUNTY
LODGEMENT DATE 2016-02-23
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 42
ENVIRONMENT IMPACT POTENTIAL 75
ENERGY CONSUMPTION CURRENT 285
ENERGY CONSUMPTION POTENTIAL 93
CO2 EMISSIONS CURRENT 5.4
CO2 EMISS CURR PER FLOOR AREA 74
CO2 EMISSIONS POTENTIAL 2.1
LIGHTING COST CURRENT 57
LIGHTING COST POTENTIAL 57
HEATING COST CURRENT 597
HEATING COST POTENTIAL 425
HOT WATER COST CURRENT 317
HOT WATER COST POTENTIAL 84
TOTAL FLOOR AREA 74
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, TRVs and bypass
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 2
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 85
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system, no cylinder thermostat
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Very Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, dual fuel (mineral and wood)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 150 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, oil
MAINHEAT ENERGY EFF Poor
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION Programmer, TRVs and bypass
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 85% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL oil (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.43
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 3, Chapel Green, Appleton Roebuck
LOCAL AUTHORITY LABEL North Yorkshire
CONSTITUENCY LABEL Wetherby and Easingwold
POSTTOWN YORK
CONSTRUCTION AGE BAND England and Wales: 1930-1949
LODGEMENT DATETIME 2016-02-23 18:04:39
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 13
LOW ENERGY FIXED LIGHT COUNT 11
UPRN 100050528169
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2016.csv
COUNTRY England
REGION E12000003
Address display
Nation ew