Energy Performance Certificate

16, Henry Close, CO15 1EN

EPC Report

Energy rating

Current: 38 F | Potential: 84 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 38 F Current: 38 F 84 B Potential: 84 B

Environmental impact (CO₂)

Current: 21 | Potential: 65
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 21 Current: 21 65 Potential: 65
Field Value
LMK KEY 8281-7922-6840-7249-3922
ADDRESS1 16, Henry Close
ADDRESS2
ADDRESS3
POSTCODE CO15 1EN
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 38
POTENTIAL ENERGY EFFICIENCY 84
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2019-02-21
LOCAL AUTHORITY E07000076
CONSTITUENCY E14001174
COUNTY
LODGEMENT DATE 2019-04-03
TRANSACTION TYPE Non-marketed sale
ENVIRONMENT IMPACT CURRENT 21
ENVIRONMENT IMPACT POTENTIAL 65
ENERGY CONSUMPTION CURRENT 695
ENERGY CONSUMPTION POTENTIAL 226
CO2 EMISSIONS CURRENT 8.3
CO2 EMISS CURR PER FLOOR AREA 117
CO2 EMISSIONS POTENTIAL 2.7
LIGHTING COST CURRENT 67
LIGHTING COST POTENTIAL 67
HEATING COST CURRENT 1341
HEATING COST POTENTIAL 539
HOT WATER COST CURRENT 179
HOT WATER COST POTENTIAL 100
TOTAL FLOOR AREA 71
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 1
LOW ENERGY LIGHTING 88
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 88% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.4
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 16, Henry Close
LOCAL AUTHORITY LABEL Tendring
CONSTITUENCY LABEL Clacton
POSTTOWN CLACTON-ON-SEA
CONSTRUCTION AGE BAND England and Wales: 1991-1995
LODGEMENT DATETIME 2019-04-03 11:24:51
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 8
LOW ENERGY FIXED LIGHT COUNT 7
UPRN 100090606127
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2019.csv
COUNTRY England
REGION E12000006
Address display
Nation ew