Energy Performance Certificate

59, Emery Street, L4 5UY

EPC Report

Energy rating

Current: 20 G | Potential: 92 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 20 G Current: 20 G 92 A Potential: 92 A

Environmental impact (CO₂)

Current: 33 | Potential: 92
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 33 Current: 33 92 Potential: 92
Field Value
LMK KEY 8280-7922-6850-4877-5206
ADDRESS1 59, Emery Street
ADDRESS2
ADDRESS3
POSTCODE L4 5UY
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING G
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 20
POTENTIAL ENERGY EFFICIENCY 92
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2020-02-03
LOCAL AUTHORITY E08000012
CONSTITUENCY E14001339
COUNTY
LODGEMENT DATE 2020-02-05
TRANSACTION TYPE ECO assessment
ENVIRONMENT IMPACT CURRENT 33
ENVIRONMENT IMPACT POTENTIAL 92
ENERGY CONSUMPTION CURRENT 547
ENERGY CONSUMPTION POTENTIAL 39
CO2 EMISSIONS CURRENT 5.8
CO2 EMISS CURR PER FLOOR AREA 93
CO2 EMISSIONS POTENTIAL 0.5
LIGHTING COST CURRENT 81
LIGHTING COST POTENTIAL 52
HEATING COST CURRENT 1477
HEATING COST POTENTIAL 266
HOT WATER COST CURRENT 485
HOT WATER COST POTENTIAL 67
TOTAL FLOOR AREA 63
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS No thermostatic control of room temperature
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 1
LOW ENERGY LIGHTING 44
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, standard tariff
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Portable electric heaters assumed for most rooms
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION No thermostatic control of room temperature
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 44% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.56
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 59, Emery Street
LOCAL AUTHORITY LABEL Liverpool
CONSTITUENCY LABEL Liverpool Walton
POSTTOWN LIVERPOOL
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2020-02-05 16:25:51
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 9
LOW ENERGY FIXED LIGHT COUNT 4
UPRN 38052686
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2020.csv
COUNTRY England
REGION E12000002
Address display
Nation ew