Energy Performance Certificate
36, Cheltenham Street, BA2 3EX
Energy rating
Current: 91 B | Potential: 91 B
Environmental impact (CO₂)
Current: 92
| Potential: 92
| Field | Value |
|---|---|
| LMK KEY | 8276-7639-4100-2198-4902 |
| ADDRESS1 | 36, Cheltenham Street |
| ADDRESS2 | — |
| ADDRESS3 | — |
| POSTCODE | BA2 3EX |
| BUILDING REFERENCE NUMBER | — |
| CURRENT ENERGY RATING | B |
| POTENTIAL ENERGY RATING | B |
| CURRENT ENERGY EFFICIENCY | 91 |
| POTENTIAL ENERGY EFFICIENCY | 91 |
| PROPERTY TYPE | House |
| BUILT FORM | — |
| INSPECTION DATE | 2016-01-08 |
| LOCAL AUTHORITY | E06000022 |
| CONSTITUENCY | E14001080 |
| COUNTY | — |
| LODGEMENT DATE | 2016-01-12 |
| TRANSACTION TYPE | New dwelling |
| ENVIRONMENT IMPACT CURRENT | 92 |
| ENVIRONMENT IMPACT POTENTIAL | 92 |
| ENERGY CONSUMPTION CURRENT | 38 |
| ENERGY CONSUMPTION POTENTIAL | 38 |
| CO2 EMISSIONS CURRENT | 1.1 |
| CO2 EMISS CURR PER FLOOR AREA | 7 |
| CO2 EMISSIONS POTENTIAL | 1.1 |
| LIGHTING COST CURRENT | 79 |
| LIGHTING COST POTENTIAL | 79 |
| HEATING COST CURRENT | 354 |
| HEATING COST POTENTIAL | 354 |
| HOT WATER COST CURRENT | 49 |
| HOT WATER COST POTENTIAL | 49 |
| TOTAL FLOOR AREA | 155 |
| ENERGY TARIFF | standard tariff |
| MAINS GAS FLAG | — |
| FLOOR LEVEL | — |
| FLAT TOP STOREY | N |
| FLAT STOREY COUNT | 3 |
| MAIN HEATING CONTROLS | Time and temperature zone control |
| MULTI GLAZE PROPORTION | 100 |
| GLAZED TYPE | — |
| GLAZED AREA | — |
| EXTENSION COUNT | — |
| NUMBER HABITABLE ROOMS | — |
| NUMBER HEATED ROOMS | — |
| LOW ENERGY LIGHTING | 100 |
| NUMBER OPEN FIREPLACES | 0 |
| HOTWATER DESCRIPTION | From main system, plus solar |
| HOT WATER ENERGY EFF | Good |
| HOT WATER ENV EFF | Very Good |
| FLOOR DESCRIPTION | Average thermal transmittance 0.12 W/m²K |
| FLOOR ENERGY EFF | Very Good |
| FLOOR ENV EFF | Very Good |
| WINDOWS DESCRIPTION | High performance glazing |
| WINDOWS ENERGY EFF | Very Good |
| WINDOWS ENV EFF | Very Good |
| WALLS DESCRIPTION | Average thermal transmittance 0.16 W/m²K |
| WALLS ENERGY EFF | Very Good |
| WALLS ENV EFF | Very Good |
| SECONDHEAT DESCRIPTION | None |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| ROOF DESCRIPTION | Average thermal transmittance 0.11 W/m²K |
| ROOF ENERGY EFF | Very Good |
| ROOF ENV EFF | Very Good |
| MAINHEAT DESCRIPTION | Boiler & underfloor, mains gas |
| MAINHEAT ENERGY EFF | Good |
| MAINHEAT ENV EFF | Good |
| MAINHEATCONT DESCRIPTION | Time and temperature zone control |
| MAINHEATC ENERGY EFF | Very Good |
| MAINHEATC ENV EFF | Very Good |
| LIGHTING DESCRIPTION | Low energy lighting in all fixed outlets |
| LIGHTING ENERGY EFF | Very Good |
| LIGHTING ENV EFF | Very Good |
| MAIN FUEL | Gas: mains gas |
| WIND TURBINE COUNT | 0 |
| HEAT LOSS CORRIDOR | — |
| UNHEATED CORRIDOR LENGTH | — |
| FLOOR HEIGHT | 2.5 |
| PHOTO SUPPLY | — |
| SOLAR WATER HEATING FLAG | — |
| MECHANICAL VENTILATION | — |
| ADDRESS | 36, Cheltenham Street |
| LOCAL AUTHORITY LABEL | Bath and North East Somerset |
| CONSTITUENCY LABEL | Bath |
| POSTTOWN | BATH |
| CONSTRUCTION AGE BAND | 2016 |
| LODGEMENT DATETIME | 2016-01-12 11:55:13 |
| TENURE | unknown |
| FIXED LIGHTING OUTLETS COUNT | 15 |
| LOW ENERGY FIXED LIGHT COUNT | 15 |
| UPRN | 10023114554 |
| UPRN SOURCE | Energy Assessor |
| REPORT TYPE | 3 |
| Source file | certificates-2016.csv |
| COUNTRY | England |
| REGION | E12000009 |
| Address display | — |
| Nation | ew |