Energy Performance Certificate

17 Beaumont Village, Warmwell Road, Crossways, DT2 8FU

EPC Report

Energy rating

Current: 81 B | Potential: 105 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 81 B Current: 81 B 105 A Potential: 105 A

Environmental impact (CO₂)

Current: 83 | Potential: 104
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 83 Current: 83 104 Potential: 104
Field Value
LMK KEY 8273-7827-5960-4050-9922
ADDRESS1 17 Beaumont Village
ADDRESS2 Warmwell Road
ADDRESS3 Crossways
POSTCODE DT2 8FU
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING B
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 81
POTENTIAL ENERGY EFFICIENCY 105
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2017-03-20
LOCAL AUTHORITY E06000059
CONSTITUENCY E14001485
COUNTY
LODGEMENT DATE 2017-04-06
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 83
ENVIRONMENT IMPACT POTENTIAL 104
ENERGY CONSUMPTION CURRENT 89
ENERGY CONSUMPTION POTENTIAL -37
CO2 EMISSIONS CURRENT 2.3
CO2 EMISS CURR PER FLOOR AREA 15
CO2 EMISSIONS POTENTIAL -1.0
LIGHTING COST CURRENT 86
LIGHTING COST POTENTIAL 86
HEATING COST CURRENT 267
HEATING COST POTENTIAL 267
HOT WATER COST CURRENT 350
HOT WATER COST POTENTIAL 222
TOTAL FLOOR AREA 156
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Time and temperature zone control
MULTI GLAZE PROPORTION 100
GLAZED TYPE double, known data
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 6
NUMBER HEATED ROOMS 6
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Suspended, insulated (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION High performance glazing
WINDOWS ENERGY EFF Very Good
WINDOWS ENV EFF Very Good
WALLS DESCRIPTION Timber frame, as built, insulated (assumed)
WALLS ENERGY EFF Very Good
WALLS ENV EFF Very Good
SECONDHEAT DESCRIPTION Room heaters, wood logs
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Flat, insulated (assumed)
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Air source heat pump, underfloor, electric
MAINHEAT ENERGY EFF Very Good
MAINHEAT ENV EFF Very Good
MAINHEATCONT DESCRIPTION Time and temperature zone control
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.41
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 17 Beaumont Village, Warmwell Road, Crossways
LOCAL AUTHORITY LABEL Dorset
CONSTITUENCY LABEL South Dorset
POSTTOWN DORCHESTER
CONSTRUCTION AGE BAND England and Wales: 2012 onwards
LODGEMENT DATETIME 2017-04-06 22:30:36
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 36
LOW ENERGY FIXED LIGHT COUNT 36
UPRN 10023250647
UPRN SOURCE Address Matched
REPORT TYPE 2
Source file certificates-2017.csv
COUNTRY England
REGION E12000009
Address display
Nation ew