Energy Performance Certificate

6, Ellis Close, Quorn, LE12 8SH

EPC Report

Energy rating

Current: 48 E | Potential: 78 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 48 E Current: 48 E 78 C Potential: 78 C

Environmental impact (CO₂)

Current: 47 | Potential: 76
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 47 Current: 47 76 Potential: 76
Field Value
LMK KEY 8272-7929-0829-1235-8902
ADDRESS1 6, Ellis Close
ADDRESS2 Quorn
ADDRESS3
POSTCODE LE12 8SH
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 48
POTENTIAL ENERGY EFFICIENCY 78
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2012-11-05
LOCAL AUTHORITY E07000130
CONSTITUENCY E14001342
COUNTY
LODGEMENT DATE 2012-11-06
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 47
ENVIRONMENT IMPACT POTENTIAL 76
ENERGY CONSUMPTION CURRENT 313
ENERGY CONSUMPTION POTENTIAL 132
CO2 EMISSIONS CURRENT 5.5
CO2 EMISS CURR PER FLOOR AREA 59
CO2 EMISSIONS POTENTIAL 2.4
LIGHTING COST CURRENT 109
LIGHTING COST POTENTIAL 54
HEATING COST CURRENT 860
HEATING COST POTENTIAL 598
HOT WATER COST CURRENT 222
HOT WATER COST POTENTIAL 71
TOTAL FLOOR AREA 93
ENERGY TARIFF dual
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 6
NUMBER HEATED ROOMS 6
LOW ENERGY LIGHTING 0
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Very Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 300+ mm loft insulation
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION No low energy lighting
LIGHTING ENERGY EFF Very Poor
LIGHTING ENV EFF Very Poor
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.31
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 6, Ellis Close, Quorn
LOCAL AUTHORITY LABEL Charnwood
CONSTITUENCY LABEL Loughborough
POSTTOWN LOUGHBOROUGH
CONSTRUCTION AGE BAND England and Wales: 1983-1990
LODGEMENT DATETIME 2012-11-06 12:36:04
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 7
LOW ENERGY FIXED LIGHT COUNT 0
UPRN 100030441869
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2012.csv
COUNTRY England
REGION E12000004
Address display
Nation ew