Energy Performance Certificate

132 Victoria Mill, Town End Road, Draycott, DE72 3WH

EPC Report

Energy rating

Current: 25 F | Potential: 44 E
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 25 F Current: 25 F 44 E Potential: 44 E

Environmental impact (CO₂)

Current: 28 | Potential: 31
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 28 Current: 28 31 Potential: 31
Field Value
LMK KEY 8271-7326-6270-9593-2926
ADDRESS1 132 Victoria Mill
ADDRESS2 Town End Road
ADDRESS3 Draycott
POSTCODE DE72 3WH
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING E
CURRENT ENERGY EFFICIENCY 25
POTENTIAL ENERGY EFFICIENCY 44
PROPERTY TYPE Flat
BUILT FORM Mid-Terrace
INSPECTION DATE 2019-06-27
LOCAL AUTHORITY E07000036
CONSTITUENCY E14001228
COUNTY
LODGEMENT DATE 2019-07-03
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 28
ENVIRONMENT IMPACT POTENTIAL 31
ENERGY CONSUMPTION CURRENT 531
ENERGY CONSUMPTION POTENTIAL 494
CO2 EMISSIONS CURRENT 9.6
CO2 EMISS CURR PER FLOOR AREA 90
CO2 EMISSIONS POTENTIAL 9.0
LIGHTING COST CURRENT 76
LIGHTING COST POTENTIAL 78
HEATING COST CURRENT 2367
HEATING COST POTENTIAL 1642
HOT WATER COST CURRENT 235
HOT WATER COST POTENTIAL 235
TOTAL FLOOR AREA 107
ENERGY TARIFF Unknown
MAINS GAS FLAG N
FLOOR LEVEL 3
FLAT TOP STOREY Y
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer and appliance thermostats
MULTI GLAZE PROPORTION 0
GLAZED TYPE not defined
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Single glazed
WINDOWS ENERGY EFF Very Poor
WINDOWS ENV EFF Very Poor
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Room heaters, electric
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION Programmer and appliance thermostats
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR unheated corridor
UNHEATED CORRIDOR LENGTH 5.18
FLOOR HEIGHT 2.7
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 132 Victoria Mill, Town End Road, Draycott
LOCAL AUTHORITY LABEL Erewash
CONSTITUENCY LABEL Erewash
POSTTOWN DERBY
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2019-07-03 07:54:31
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 7
LOW ENERGY FIXED LIGHT COUNT 7
UPRN 10090662004
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2019.csv
COUNTRY England
REGION E12000004
Address display
Nation ew