Energy Performance Certificate

Hawthorns, Main Road, Withern, LN13 0LD

EPC Report

Energy rating

Current: 67 D | Potential: 85 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 67 D Current: 67 D 85 B Potential: 85 B

Environmental impact (CO₂)

Current: 70 | Potential: 86
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 70 Current: 70 86 Potential: 86
Field Value
LMK KEY 8255-6326-8170-9302-7906
ADDRESS1 Hawthorns
ADDRESS2 Main Road
ADDRESS3 Withern
POSTCODE LN13 0LD
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 67
POTENTIAL ENERGY EFFICIENCY 85
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2015-06-02
LOCAL AUTHORITY E07000137
CONSTITUENCY E14001343
COUNTY
LODGEMENT DATE 2015-06-04
TRANSACTION TYPE RHI application
ENVIRONMENT IMPACT CURRENT 70
ENVIRONMENT IMPACT POTENTIAL 86
ENERGY CONSUMPTION CURRENT 162
ENERGY CONSUMPTION POTENTIAL 72
CO2 EMISSIONS CURRENT 5.6
CO2 EMISS CURR PER FLOOR AREA 27
CO2 EMISSIONS POTENTIAL 2.5
LIGHTING COST CURRENT 94
LIGHTING COST POTENTIAL 94
HEATING COST CURRENT 1256
HEATING COST POTENTIAL 1258
HOT WATER COST CURRENT 254
HOT WATER COST POTENTIAL 173
TOTAL FLOOR AREA 205
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Time and temperature zone control
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 10
NUMBER HEATED ROOMS 10
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, insulated (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Timber frame, as built, insulated (assumed)
WALLS ENERGY EFF Very Good
WALLS ENV EFF Very Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, insulated (assumed)
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Air source heat pump, underfloor, electric
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Time and temperature zone control
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.2589
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION mechanical, supply and extract
ADDRESS Hawthorns, Main Road, Withern
LOCAL AUTHORITY LABEL East Lindsey
CONSTITUENCY LABEL Louth and Horncastle
POSTTOWN ALFORD
CONSTRUCTION AGE BAND England and Wales: 2012 onwards
LODGEMENT DATETIME 2015-06-04 12:11:21
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 26
LOW ENERGY FIXED LIGHT COUNT 26
UPRN 10093437802
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2015.csv
COUNTRY England
REGION E12000004
Address display
Nation ew