Energy Performance Certificate

63, Hanson Park, Northam, EX39 3SB

EPC Report

Energy rating

Current: 55 D | Potential: 81 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 55 D Current: 55 D 81 B Potential: 81 B

Environmental impact (CO₂)

Current: 46 | Potential: 77
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 46 Current: 46 77 Potential: 77
Field Value
LMK KEY 8248-7429-0770-1979-7972
ADDRESS1 63, Hanson Park
ADDRESS2 Northam
ADDRESS3
POSTCODE EX39 3SB
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 55
POTENTIAL ENERGY EFFICIENCY 81
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2018-01-31
LOCAL AUTHORITY E07000046
CONSTITUENCY E14001552
COUNTY
LODGEMENT DATE 2018-02-01
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 46
ENVIRONMENT IMPACT POTENTIAL 77
ENERGY CONSUMPTION CURRENT 298
ENERGY CONSUMPTION POTENTIAL 108
CO2 EMISSIONS CURRENT 6.1
CO2 EMISS CURR PER FLOOR AREA 53
CO2 EMISSIONS POTENTIAL 2.2
LIGHTING COST CURRENT 96
LIGHTING COST POTENTIAL 75
HEATING COST CURRENT 960
HEATING COST POTENTIAL 583
HOT WATER COST CURRENT 208
HOT WATER COST POTENTIAL 75
TOTAL FLOOR AREA 116
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, no room thermostat
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 7
NUMBER HEATED ROOMS 7
LOW ENERGY LIGHTING 71
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 150 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, no room thermostat
MAINHEATC ENERGY EFF Very Poor
MAINHEATC ENV EFF Very Poor
LIGHTING DESCRIPTION Low energy lighting in 71% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.3
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 63, Hanson Park, Northam
LOCAL AUTHORITY LABEL Torridge
CONSTITUENCY LABEL Torridge and Tavistock
POSTTOWN BIDEFORD
CONSTRUCTION AGE BAND England and Wales: 1991-1995
LODGEMENT DATETIME 2018-02-01 12:13:51
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 14
LOW ENERGY FIXED LIGHT COUNT 10
UPRN 100040375549
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2018.csv
COUNTRY England
REGION E12000009
Address display
Nation ew