Energy Performance Certificate

5, Tremayne Road, Carharrack, TR16 5RF

EPC Report

Energy rating

Current: 30 F | Potential: 74 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 30 F Current: 30 F 74 C Potential: 74 C

Environmental impact (CO₂)

Current: 26 | Potential: 66
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 26 Current: 26 66 Potential: 66
Field Value
LMK KEY 8248-7325-4670-7969-4972
ADDRESS1 5, Tremayne Road
ADDRESS2 Carharrack
ADDRESS3
POSTCODE TR16 5RF
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 30
POTENTIAL ENERGY EFFICIENCY 74
PROPERTY TYPE Bungalow
BUILT FORM Detached
INSPECTION DATE 2018-05-31
LOCAL AUTHORITY E06000052
CONSTITUENCY E14001148
COUNTY
LODGEMENT DATE 2018-06-01
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 26
ENVIRONMENT IMPACT POTENTIAL 66
ENERGY CONSUMPTION CURRENT 355
ENERGY CONSUMPTION POTENTIAL 105
CO2 EMISSIONS CURRENT 8.5
CO2 EMISS CURR PER FLOOR AREA 91
CO2 EMISSIONS POTENTIAL 2.9
LIGHTING COST CURRENT 94
LIGHTING COST POTENTIAL 62
HEATING COST CURRENT 868
HEATING COST POTENTIAL 469
HOT WATER COST CURRENT 229
HOT WATER COST POTENTIAL 65
TOTAL FLOOR AREA 93
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 50
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION From main system, no cylinder thermostat
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Very Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION Room heaters, dual fuel (mineral and wood)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 250 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, oil
MAINHEAT ENERGY EFF Poor
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 50% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL oil (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.45
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 5, Tremayne Road, Carharrack
LOCAL AUTHORITY LABEL Cornwall
CONSTITUENCY LABEL Camborne and Redruth
POSTTOWN REDRUTH
CONSTRUCTION AGE BAND England and Wales: 1967-1975
LODGEMENT DATETIME 2018-06-01 06:28:10
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 12
LOW ENERGY FIXED LIGHT COUNT 6
UPRN 100040077688
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2018.csv
COUNTRY England
REGION E12000009
Address display
Nation ew