Energy Performance Certificate

67 ERNEST DAWES AVENUE, PRIORSLEE, TF2 9XA

EPC Report

Energy rating

Current: 85 B | Potential: 85 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 85 B Current: 85 B 85 B Potential: 85 B

Environmental impact (CO₂)

Current: 84 | Potential: 84
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 84 Current: 84 84 Potential: 84
Field Value
LMK KEY 8239-6336-2000-0342-7226
ADDRESS1 67 ERNEST DAWES AVENUE
ADDRESS2 PRIORSLEE
ADDRESS3
POSTCODE TF2 9XA
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING B
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 85
POTENTIAL ENERGY EFFICIENCY 85
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2021-06-22
LOCAL AUTHORITY E06000020
CONSTITUENCY E14001541
COUNTY
LODGEMENT DATE 2021-06-22
TRANSACTION TYPE New dwelling
ENVIRONMENT IMPACT CURRENT 84
ENVIRONMENT IMPACT POTENTIAL 84
ENERGY CONSUMPTION CURRENT 85
ENERGY CONSUMPTION POTENTIAL 85
CO2 EMISSIONS CURRENT 2.4
CO2 EMISS CURR PER FLOOR AREA 15
CO2 EMISSIONS POTENTIAL 2.4
LIGHTING COST CURRENT 100
LIGHTING COST POTENTIAL 100
HEATING COST CURRENT 383
HEATING COST POTENTIAL 383
HOT WATER COST CURRENT 101
HOT WATER COST POTENTIAL 101
TOTAL FLOOR AREA 162
ENERGY TARIFF standard tariff
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Time and temperature zone control
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT
NUMBER HABITABLE ROOMS
NUMBER HEATED ROOMS
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Average thermal transmittance 0.17 W/m²K
FLOOR ENERGY EFF Very Good
FLOOR ENV EFF Very Good
WINDOWS DESCRIPTION High performance glazing
WINDOWS ENERGY EFF Very Good
WINDOWS ENV EFF Very Good
WALLS DESCRIPTION Average thermal transmittance 0.28 W/m²K
WALLS ENERGY EFF Very Good
WALLS ENV EFF Very Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Average thermal transmittance 0.11 W/m²K
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Time and temperature zone control
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL Gas: mains gas
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.82
PHOTO SUPPLY
SOLAR WATER HEATING FLAG
MECHANICAL VENTILATION
ADDRESS 67 ERNEST DAWES AVENUE, PRIORSLEE
LOCAL AUTHORITY LABEL Telford and Wrekin
CONSTITUENCY LABEL Telford
POSTTOWN TELFORD
CONSTRUCTION AGE BAND 2021
LODGEMENT DATETIME 2021-06-22 11:37:06
TENURE unknown
FIXED LIGHTING OUTLETS COUNT 30
LOW ENERGY FIXED LIGHT COUNT 30
UPRN 10094516926
UPRN SOURCE Energy Assessor
REPORT TYPE 3
Source file certificates-2021.csv
COUNTRY England
REGION E12000005
Address display
Nation ew