Energy Performance Certificate

239, Oxford Road, RG1 7PX

EPC Report

Energy rating

Current: 23 F | Potential: 64 D
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 23 F Current: 23 F 64 D Potential: 64 D

Environmental impact (CO₂)

Current: 34 | Potential: 39
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 34 Current: 34 39 Potential: 39
Field Value
LMK KEY 8236-7629-1030-1833-1902
ADDRESS1 239, Oxford Road
ADDRESS2
ADDRESS3
POSTCODE RG1 7PX
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING D
CURRENT ENERGY EFFICIENCY 23
POTENTIAL ENERGY EFFICIENCY 64
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2016-01-07
LOCAL AUTHORITY E06000038
CONSTITUENCY E14001438
COUNTY
LODGEMENT DATE 2016-01-18
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 34
ENVIRONMENT IMPACT POTENTIAL 39
ENERGY CONSUMPTION CURRENT 335
ENERGY CONSUMPTION POTENTIAL 289
CO2 EMISSIONS CURRENT 15
CO2 EMISS CURR PER FLOOR AREA 57
CO2 EMISSIONS POTENTIAL 13
LIGHTING COST CURRENT 144
LIGHTING COST POTENTIAL 164
HEATING COST CURRENT 4005
HEATING COST POTENTIAL 1998
HOT WATER COST CURRENT 331
HOT WATER COST POTENTIAL 115
TOTAL FLOOR AREA 268
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 4
MAIN HEATING CONTROLS Programmer and appliance thermostats
MULTI GLAZE PROPORTION 0
GLAZED TYPE not defined
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 11
NUMBER HEATED ROOMS 11
LOW ENERGY LIGHTING 67
NUMBER OPEN FIREPLACES 7
HOTWATER DESCRIPTION Electric immersion, standard tariff
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Single glazed
WINDOWS ENERGY EFF Very Poor
WINDOWS ENV EFF Very Poor
WALLS DESCRIPTION Solid brick, with internal insulation
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Room heaters, electric
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION Programmer and appliance thermostats
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 67% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.23
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 239, Oxford Road
LOCAL AUTHORITY LABEL Reading
CONSTITUENCY LABEL Reading Central
POSTTOWN READING
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2016-01-18 15:44:08
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 15
LOW ENERGY FIXED LIGHT COUNT 10
UPRN 310007522
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2016.csv
COUNTRY England
REGION E12000008
Address display
Nation ew