Energy Performance Certificate

1, West Meadows, Allington, NG32 2ET

EPC Report

Energy rating

Current: 83 B | Potential: 83 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 83 B Current: 83 B 83 B Potential: 83 B

Environmental impact (CO₂)

Current: 79 | Potential: 79
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 79 Current: 79 79 Potential: 79
Field Value
LMK KEY 8236-7626-4350-8554-1922
ADDRESS1 1, West Meadows
ADDRESS2 Allington
ADDRESS3
POSTCODE NG32 2ET
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING B
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 83
POTENTIAL ENERGY EFFICIENCY 83
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2016-06-24
LOCAL AUTHORITY E07000141
CONSTITUENCY E14001253
COUNTY
LODGEMENT DATE 2016-06-24
TRANSACTION TYPE Non-marketed sale
ENVIRONMENT IMPACT CURRENT 79
ENVIRONMENT IMPACT POTENTIAL 79
ENERGY CONSUMPTION CURRENT 100
ENERGY CONSUMPTION POTENTIAL 100
CO2 EMISSIONS CURRENT 6.7
CO2 EMISS CURR PER FLOOR AREA 18
CO2 EMISSIONS POTENTIAL 6.7
LIGHTING COST CURRENT 134
LIGHTING COST POTENTIAL 134
HEATING COST CURRENT 1343
HEATING COST POTENTIAL 1343
HOT WATER COST CURRENT 86
HOT WATER COST POTENTIAL 86
TOTAL FLOOR AREA 379
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Time and temperature zone control
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 10
NUMBER HEATED ROOMS 10
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system, plus solar
HOT WATER ENERGY EFF Very Good
HOT WATER ENV EFF Very Good
FLOOR DESCRIPTION Solid, insulated (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, insulated (assumed)
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Time and temperature zone control
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.67
PHOTO SUPPLY 5
SOLAR WATER HEATING FLAG Y
MECHANICAL VENTILATION natural
ADDRESS 1, West Meadows, Allington
LOCAL AUTHORITY LABEL South Kesteven
CONSTITUENCY LABEL Grantham and Bourne
POSTTOWN GRANTHAM
CONSTRUCTION AGE BAND England and Wales: 2003-2006
LODGEMENT DATETIME 2016-06-24 12:59:44
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 36
LOW ENERGY FIXED LIGHT COUNT 36
UPRN 10007250204
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2016.csv
COUNTRY England
REGION E12000004
Address display
Nation ew