Energy Performance Certificate

Fox Barn, Hatchett Hill, Lower Chute, SP11 9DU

EPC Report

Energy rating

Current: 102 A | Potential: 102 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 102 A Current: 102 A 102 A Potential: 102 A

Environmental impact (CO₂)

Current: 103 | Potential: 103
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 103 Current: 103 103 Potential: 103
Field Value
LMK KEY 8232-7532-0469-7339-8906
ADDRESS1 Fox Barn
ADDRESS2 Hatchett Hill
ADDRESS3 Lower Chute
POSTCODE SP11 9DU
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING A
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 102
POTENTIAL ENERGY EFFICIENCY 102
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2012-12-01
LOCAL AUTHORITY E06000054
CONSTITUENCY E14001217
COUNTY
LODGEMENT DATE 2013-05-08
TRANSACTION TYPE New dwelling
ENVIRONMENT IMPACT CURRENT 103
ENVIRONMENT IMPACT POTENTIAL 103
ENERGY CONSUMPTION CURRENT -2
ENERGY CONSUMPTION POTENTIAL -2
CO2 EMISSIONS CURRENT -0.5
CO2 EMISS CURR PER FLOOR AREA -2.6
CO2 EMISSIONS POTENTIAL -0.5
LIGHTING COST CURRENT 81
LIGHTING COST POTENTIAL 81
HEATING COST CURRENT 199
HEATING COST POTENTIAL 189
HOT WATER COST CURRENT 55
HOT WATER COST POTENTIAL 66
TOTAL FLOOR AREA 189
ENERGY TARIFF off-peak 7 hour
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer and appliance thermostats
MULTI GLAZE PROPORTION
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT
NUMBER HABITABLE ROOMS
NUMBER HEATED ROOMS
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak, plus solar
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Average thermal transmittance 0.11 W/m²K
FLOOR ENERGY EFF Very Good
FLOOR ENV EFF Very Good
WINDOWS DESCRIPTION High performance glazing
WINDOWS ENERGY EFF Very Good
WINDOWS ENV EFF Very Good
WALLS DESCRIPTION Average thermal transmittance 0.14 W/m²K
WALLS ENERGY EFF Very Good
WALLS ENV EFF Very Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Average thermal transmittance 0.1 W/m²K
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Room heaters, wood logs
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Good
MAINHEATCONT DESCRIPTION Programmer and appliance thermostats
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL Solid fuel: wood logs
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.1
PHOTO SUPPLY
SOLAR WATER HEATING FLAG
MECHANICAL VENTILATION
ADDRESS Fox Barn, Hatchett Hill, Lower Chute
LOCAL AUTHORITY LABEL Wiltshire
CONSTITUENCY LABEL East Wiltshire
POSTTOWN ANDOVER
CONSTRUCTION AGE BAND 2012
LODGEMENT DATETIME 2013-05-08 16:50:12
TENURE
FIXED LIGHTING OUTLETS COUNT 25
LOW ENERGY FIXED LIGHT COUNT 25
UPRN 10090711876
UPRN SOURCE Energy Assessor
REPORT TYPE 3
Source file certificates-2013.csv
COUNTRY England
REGION E12000009
Address display
Nation ew