Energy Performance Certificate

73b, Talbot Road, SK14 4EX

EPC Report

Energy rating

Current: 85 B | Potential: 94 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 85 B Current: 85 B 94 A Potential: 94 A

Environmental impact (CO₂)

Current: 86 | Potential: 95
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 86 Current: 86 95 Potential: 95
Field Value
LMK KEY 8221-7538-6360-6544-9996
ADDRESS1 73b, Talbot Road
ADDRESS2
ADDRESS3
POSTCODE SK14 4EX
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING B
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 85
POTENTIAL ENERGY EFFICIENCY 94
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2019-08-14
LOCAL AUTHORITY E08000008
CONSTITUENCY E14001515
COUNTY
LODGEMENT DATE 2019-08-14
TRANSACTION TYPE New dwelling
ENVIRONMENT IMPACT CURRENT 86
ENVIRONMENT IMPACT POTENTIAL 95
ENERGY CONSUMPTION CURRENT 87
ENERGY CONSUMPTION POTENTIAL 35
CO2 EMISSIONS CURRENT 1.8
CO2 EMISS CURR PER FLOOR AREA 15
CO2 EMISSIONS POTENTIAL 0.8
LIGHTING COST CURRENT 83
LIGHTING COST POTENTIAL 83
HEATING COST CURRENT 300
HEATING COST POTENTIAL 300
HOT WATER COST CURRENT 78
HOT WATER COST POTENTIAL 49
TOTAL FLOOR AREA 117
ENERGY TARIFF standard tariff
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 3
MAIN HEATING CONTROLS Time and temperature zone control
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT
NUMBER HABITABLE ROOMS
NUMBER HEATED ROOMS
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Average thermal transmittance 0.14 W/m²K
FLOOR ENERGY EFF Very Good
FLOOR ENV EFF Very Good
WINDOWS DESCRIPTION High performance glazing
WINDOWS ENERGY EFF Very Good
WINDOWS ENV EFF Very Good
WALLS DESCRIPTION Average thermal transmittance 0.29 W/m²K
WALLS ENERGY EFF Very Good
WALLS ENV EFF Very Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Average thermal transmittance 0.19 W/m²K
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Time and temperature zone control
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL Gas: mains gas
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.46
PHOTO SUPPLY
SOLAR WATER HEATING FLAG
MECHANICAL VENTILATION
ADDRESS 73b, Talbot Road
LOCAL AUTHORITY LABEL Tameside
CONSTITUENCY LABEL Stalybridge and Hyde
POSTTOWN HYDE
CONSTRUCTION AGE BAND 2018
LODGEMENT DATETIME 2019-08-14 14:45:26
TENURE unknown
FIXED LIGHTING OUTLETS COUNT 32
LOW ENERGY FIXED LIGHT COUNT 32
UPRN 10093147139
UPRN SOURCE Energy Assessor
REPORT TYPE 3
Source file certificates-2019.csv
COUNTRY England
REGION E12000002
Address display
Nation ew