Energy Performance Certificate

40, Fernheath Way, DA2 7PF

EPC Report

Energy rating

Current: 72 C | Potential: 88 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 72 C Current: 72 C 88 B Potential: 88 B

Environmental impact (CO₂)

Current: 71 | Potential: 88
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 71 Current: 71 88 Potential: 88
Field Value
LMK KEY 8221-7022-6010-5358-6926
ADDRESS1 40, Fernheath Way
ADDRESS2
ADDRESS3
POSTCODE DA2 7PF
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 72
POTENTIAL ENERGY EFFICIENCY 88
PROPERTY TYPE Bungalow
BUILT FORM Semi-Detached
INSPECTION DATE 2019-02-28
LOCAL AUTHORITY E07000107
CONSTITUENCY E14001191
COUNTY
LODGEMENT DATE 2019-02-28
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 71
ENVIRONMENT IMPACT POTENTIAL 88
ENERGY CONSUMPTION CURRENT 189
ENERGY CONSUMPTION POTENTIAL 62
CO2 EMISSIONS CURRENT 2.1
CO2 EMISS CURR PER FLOOR AREA 33
CO2 EMISSIONS POTENTIAL 0.7
LIGHTING COST CURRENT 92
LIGHTING COST POTENTIAL 49
HEATING COST CURRENT 362
HEATING COST POTENTIAL 336
HOT WATER COST CURRENT 77
HOT WATER COST POTENTIAL 49
TOTAL FLOOR AREA 65
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 13
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 270 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 13% of fixed outlets
LIGHTING ENERGY EFF Poor
LIGHTING ENV EFF Poor
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.44
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 40, Fernheath Way
LOCAL AUTHORITY LABEL Dartford
CONSTITUENCY LABEL Dartford
POSTTOWN DARTFORD
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2019-02-28 13:13:04
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 16
LOW ENERGY FIXED LIGHT COUNT 2
UPRN 100060861276
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2019.csv
COUNTRY England
REGION E12000008
Address display
Nation ew