Energy Performance Certificate

109 St. Helens Park Road, TN34 2JW

EPC Report

Energy rating

Current: 34 F | Potential: 71 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 34 F Current: 34 F 71 C Potential: 71 C

Environmental impact (CO₂)

Current: 29 | Potential: 64
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 29 Current: 29 64 Potential: 64
Field Value
LMK KEY 8208-7022-6919-7210-4922
ADDRESS1 109 St. Helens Park Road
ADDRESS2
ADDRESS3
POSTCODE TN34 2JW
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 34
POTENTIAL ENERGY EFFICIENCY 71
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2018-12-20
LOCAL AUTHORITY E07000062
CONSTITUENCY E14001274
COUNTY
LODGEMENT DATE 2018-12-20
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 29
ENVIRONMENT IMPACT POTENTIAL 64
ENERGY CONSUMPTION CURRENT 253
ENERGY CONSUMPTION POTENTIAL 105
CO2 EMISSIONS CURRENT 31
CO2 EMISS CURR PER FLOOR AREA 67
CO2 EMISSIONS POTENTIAL 13
LIGHTING COST CURRENT 196
LIGHTING COST POTENTIAL 201
HEATING COST CURRENT 3656
HEATING COST POTENTIAL 1611
HOT WATER COST CURRENT 163
HOT WATER COST POTENTIAL 117
TOTAL FLOOR AREA 455
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 5
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 18
NUMBER HEATED ROOMS 18
LOW ENERGY LIGHTING 76
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Some double glazing
WINDOWS ENERGY EFF Very Poor
WINDOWS ENV EFF Very Poor
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Roof room(s), ceiling insulated
ROOF ENERGY EFF Poor
ROOF ENV EFF Poor
MAINHEAT DESCRIPTION Boiler and radiators, oil
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 76% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL oil (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 3.5
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 109 St. Helens Park Road
LOCAL AUTHORITY LABEL Hastings
CONSTITUENCY LABEL Hastings and Rye
POSTTOWN HASTINGS
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2018-12-20 16:17:17
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 37
LOW ENERGY FIXED LIGHT COUNT 28
UPRN 100062632227
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2018.csv
COUNTRY England
REGION E12000008
Address display
Nation ew