Energy Performance Certificate

1 Rocombe Court Lower Rocombe, Stokeinteignhead, TQ12 4QL

EPC Report

Energy rating

Current: 28 F | Potential: 104 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 28 F Current: 28 F 104 A Potential: 104 A

Environmental impact (CO₂)

Current: 13 | Potential: 82
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 13 Current: 13 82 Potential: 82
Field Value
LMK KEY 8207-5340-4929-4497-0283
ADDRESS1 1 Rocombe Court Lower Rocombe
ADDRESS2 Stokeinteignhead
ADDRESS3
POSTCODE TQ12 4QL
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 28
POTENTIAL ENERGY EFFICIENCY 104
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2018-02-14
LOCAL AUTHORITY E07000045
CONSTITUENCY E14001381
COUNTY
LODGEMENT DATE 2018-02-14
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 13
ENVIRONMENT IMPACT POTENTIAL 82
ENERGY CONSUMPTION CURRENT 678
ENERGY CONSUMPTION POTENTIAL 57
CO2 EMISSIONS CURRENT 11
CO2 EMISS CURR PER FLOOR AREA 115
CO2 EMISSIONS POTENTIAL 0.9
LIGHTING COST CURRENT 119
LIGHTING COST POTENTIAL 71
HEATING COST CURRENT 1653
HEATING COST POTENTIAL 488
HOT WATER COST CURRENT 167
HOT WATER COST POTENTIAL 102
TOTAL FLOOR AREA 97
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 33
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Granite or whinstone, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 150 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 33% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.29
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 1 Rocombe Court Lower Rocombe, Stokeinteignhead
LOCAL AUTHORITY LABEL Teignbridge
CONSTITUENCY LABEL Newton Abbot
POSTTOWN NEWTON ABBOT
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2018-02-14 16:05:55
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 12
LOW ENERGY FIXED LIGHT COUNT 4
UPRN 10032972245
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2018.csv
COUNTRY England
REGION E12000009
Address display
Nation ew