Energy Performance Certificate

Pit Lane House, 2a Runner End, Holme-on-Spalding-Moor, YO43 4EP

EPC Report

Energy rating

Current: 97 A | Potential: 123 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 97 A Current: 97 A 123 A Potential: 123 A

Environmental impact (CO₂)

Current: 97 | Potential: 121
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 97 Current: 97 121 Potential: 121
Field Value
LMK KEY 8207-2953-7939-2797-0143
ADDRESS1 Pit Lane House
ADDRESS2 2a Runner End
ADDRESS3 Holme-on-Spalding-Moor
POSTCODE YO43 4EP
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING A
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 97
POTENTIAL ENERGY EFFICIENCY 123
PROPERTY TYPE House
BUILT FORM
INSPECTION DATE 2014-09-15
LOCAL AUTHORITY E06000011
CONSTITUENCY E14001250
COUNTY
LODGEMENT DATE 2015-10-22
TRANSACTION TYPE New dwelling
ENVIRONMENT IMPACT CURRENT 97
ENVIRONMENT IMPACT POTENTIAL 121
ENERGY CONSUMPTION CURRENT 15
ENERGY CONSUMPTION POTENTIAL -141
CO2 EMISSIONS CURRENT 0.2
CO2 EMISS CURR PER FLOOR AREA 3
CO2 EMISSIONS POTENTIAL -2.1
LIGHTING COST CURRENT 56
LIGHTING COST POTENTIAL 56
HEATING COST CURRENT 227
HEATING COST POTENTIAL 228
HOT WATER COST CURRENT 310
HOT WATER COST POTENTIAL 186
TOTAL FLOOR AREA 86
ENERGY TARIFF standard tariff
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Time and temperature zone control
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT
NUMBER HABITABLE ROOMS
NUMBER HEATED ROOMS
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Very Good
FLOOR DESCRIPTION Average thermal transmittance 0.13 W/m²K
FLOOR ENERGY EFF Very Good
FLOOR ENV EFF Very Good
WINDOWS DESCRIPTION High performance glazing
WINDOWS ENERGY EFF Very Good
WINDOWS ENV EFF Very Good
WALLS DESCRIPTION Average thermal transmittance 0.26 W/m²K
WALLS ENERGY EFF Very Good
WALLS ENV EFF Very Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Average thermal transmittance 0.14 W/m²K
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Air source heat pump, Underfloor heating, pipes in concrete slab, electric
MAINHEAT ENERGY EFF Very Good
MAINHEAT ENV EFF Very Good
MAINHEATCONT DESCRIPTION Time and temperature zone control
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL Electricity: electricity, unspecified tariff
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.434
PHOTO SUPPLY
SOLAR WATER HEATING FLAG
MECHANICAL VENTILATION
ADDRESS Pit Lane House, 2a Runner End, Holme-on-Spalding-Moor
LOCAL AUTHORITY LABEL East Riding of Yorkshire
CONSTITUENCY LABEL Goole and Pocklington
POSTTOWN YORK
CONSTRUCTION AGE BAND 2014
LODGEMENT DATETIME 2015-10-22 15:16:35
TENURE unknown
FIXED LIGHTING OUTLETS COUNT 10
LOW ENERGY FIXED LIGHT COUNT 10
UPRN 10091014016
UPRN SOURCE Energy Assessor
REPORT TYPE 3
Source file certificates-2015.csv
COUNTRY England
REGION E12000003
Address display
Nation ew