Energy Performance Certificate

2 Chalice Walk, High Street, Rusper, RH12 4FA

EPC Report

Energy rating

Current: 91 B | Potential: 93 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 91 B Current: 91 B 93 A Potential: 93 A

Environmental impact (CO₂)

Current: 92 | Potential: 94
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 92 Current: 92 94 Potential: 94
Field Value
LMK KEY 8202-8275-2139-9097-6433
ADDRESS1 2 Chalice Walk
ADDRESS2 High Street
ADDRESS3 Rusper
POSTCODE RH12 4FA
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING B
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 91
POTENTIAL ENERGY EFFICIENCY 93
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2017-04-13
LOCAL AUTHORITY E07000227
CONSTITUENCY E14001294
COUNTY
LODGEMENT DATE 2017-04-13
TRANSACTION TYPE New dwelling
ENVIRONMENT IMPACT CURRENT 92
ENVIRONMENT IMPACT POTENTIAL 94
ENERGY CONSUMPTION CURRENT 37
ENERGY CONSUMPTION POTENTIAL 24
CO2 EMISSIONS CURRENT 0.8
CO2 EMISS CURR PER FLOOR AREA 7
CO2 EMISSIONS POTENTIAL 0.5
LIGHTING COST CURRENT 69
LIGHTING COST POTENTIAL 69
HEATING COST CURRENT 298
HEATING COST POTENTIAL 299
HOT WATER COST CURRENT 116
HOT WATER COST POTENTIAL 64
TOTAL FLOOR AREA 115
ENERGY TARIFF standard tariff
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT
NUMBER HABITABLE ROOMS
NUMBER HEATED ROOMS
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Average thermal transmittance 0.09 W/m²K
FLOOR ENERGY EFF Very Good
FLOOR ENV EFF Very Good
WINDOWS DESCRIPTION High performance glazing
WINDOWS ENERGY EFF Very Good
WINDOWS ENV EFF Very Good
WALLS DESCRIPTION Average thermal transmittance 0.20 W/m²K
WALLS ENERGY EFF Very Good
WALLS ENV EFF Very Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Average thermal transmittance 0.14 W/m²K
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL Gas: mains gas
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.38
PHOTO SUPPLY
SOLAR WATER HEATING FLAG
MECHANICAL VENTILATION
ADDRESS 2 Chalice Walk, High Street, Rusper
LOCAL AUTHORITY LABEL Horsham
CONSTITUENCY LABEL Horsham
POSTTOWN HORSHAM
CONSTRUCTION AGE BAND 2017
LODGEMENT DATETIME 2017-04-13 10:21:26
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 38
LOW ENERGY FIXED LIGHT COUNT 38
UPRN 10093101078
UPRN SOURCE Energy Assessor
REPORT TYPE 3
Source file certificates-2017.csv
COUNTRY England
REGION E12000008
Address display
Nation ew