Energy Performance Certificate

102, Waverley Road, BD7 3AJ

EPC Report

Energy rating

Current: 38 F | Potential: 66 D
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 38 F Current: 38 F 66 D Potential: 66 D

Environmental impact (CO₂)

Current: 36 | Potential: 62
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 36 Current: 36 62 Potential: 62
Field Value
LMK KEY 8202-7228-0830-0158-5922
ADDRESS1 102, Waverley Road
ADDRESS2
ADDRESS3
POSTCODE BD7 3AJ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING D
CURRENT ENERGY EFFICIENCY 38
POTENTIAL ENERGY EFFICIENCY 66
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2012-08-28
LOCAL AUTHORITY E08000032
CONSTITUENCY E14001120
COUNTY
LODGEMENT DATE 2012-08-28
TRANSACTION TYPE marketed sale
ENVIRONMENT IMPACT CURRENT 36
ENVIRONMENT IMPACT POTENTIAL 62
ENERGY CONSUMPTION CURRENT 383
ENERGY CONSUMPTION POTENTIAL 200
CO2 EMISSIONS CURRENT 8.9
CO2 EMISS CURR PER FLOOR AREA 73
CO2 EMISSIONS POTENTIAL 4.7
LIGHTING COST CURRENT 103
LIGHTING COST POTENTIAL 60
HEATING COST CURRENT 1589
HEATING COST POTENTIAL 1032
HOT WATER COST CURRENT 89
HOT WATER COST POTENTIAL 91
TOTAL FLOOR AREA 122
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 3
MAIN HEATING CONTROLS No thermostatic control of room temperature
MULTI GLAZE PROPORTION 95
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 7
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 28
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Gas multipoint
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Mostly double glazing
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Sandstone, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Roof room(s), no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Room heaters, mains gas
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION No thermostatic control of room temperature
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 28% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.37
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 102, Waverley Road
LOCAL AUTHORITY LABEL Bradford
CONSTITUENCY LABEL Bradford West
POSTTOWN BRADFORD
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2012-09-03 23:04:53
TENURE
FIXED LIGHTING OUTLETS COUNT 18
LOW ENERGY FIXED LIGHT COUNT 5
UPRN 100051232916
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2012.csv
COUNTRY England
REGION E12000003
Address display
Nation ew