Energy Performance Certificate

6, Phillips Lane, BB8 8JB

EPC Report

Energy rating

Current: 34 F | Potential: 87 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 34 F Current: 34 F 87 B Potential: 87 B

Environmental impact (CO₂)

Current: 42 | Potential: 87
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 42 Current: 42 87 Potential: 87
Field Value
LMK KEY 8202-0271-5929-5207-6243
ADDRESS1 6, Phillips Lane
ADDRESS2
ADDRESS3
POSTCODE BB8 8JB
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 34
POTENTIAL ENERGY EFFICIENCY 87
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2014-02-03
LOCAL AUTHORITY E07000122
CONSTITUENCY E14001422
COUNTY
LODGEMENT DATE 2014-02-03
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 42
ENVIRONMENT IMPACT POTENTIAL 87
ENERGY CONSUMPTION CURRENT 374
ENERGY CONSUMPTION POTENTIAL 71
CO2 EMISSIONS CURRENT 6.0
CO2 EMISS CURR PER FLOOR AREA 68
CO2 EMISSIONS POTENTIAL 1.2
LIGHTING COST CURRENT 95
LIGHTING COST POTENTIAL 53
HEATING COST CURRENT 1216
HEATING COST POTENTIAL 429
HOT WATER COST CURRENT 311
HOT WATER COST POTENTIAL 71
TOTAL FLOOR AREA 89
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS None
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 0
LOW ENERGY LIGHTING 20
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Gas boiler/circulator, no cylinder thermostat
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Sandstone, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 300+ mm loft insulation
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION No system present: electric heaters assumed
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION None
MAINHEATC ENERGY EFF Very Poor
MAINHEATC ENV EFF Very Poor
LIGHTING DESCRIPTION Low energy lighting in 20% of fixed outlets
LIGHTING ENERGY EFF Poor
LIGHTING ENV EFF Poor
MAIN FUEL To be used only when there is no heating/hot-water system
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.84
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 6, Phillips Lane
LOCAL AUTHORITY LABEL Pendle
CONSTITUENCY LABEL Pendle and Clitheroe
POSTTOWN COLNE
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2014-02-03 21:15:26
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 10
LOW ENERGY FIXED LIGHT COUNT 2
UPRN 61016702
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2014.csv
COUNTRY England
REGION E12000002
Address display
Nation ew