Energy Performance Certificate

6 Balham Villas, Granby Street, CB8 8HB

EPC Report

Energy rating

Current: 14 G | Potential: 74 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 14 G Current: 14 G 74 C Potential: 74 C

Environmental impact (CO₂)

Current: 27 | Potential: 55
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 27 Current: 27 55 Potential: 55
Field Value
LMK KEY 8201-4361-1929-8427-0583
ADDRESS1 6 Balham Villas
ADDRESS2 Granby Street
ADDRESS3
POSTCODE CB8 8HB
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING G
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 14
POTENTIAL ENERGY EFFICIENCY 74
PROPERTY TYPE Flat
BUILT FORM Semi-Detached
INSPECTION DATE 2018-05-26
LOCAL AUTHORITY E07000245
CONSTITUENCY E14001578
COUNTY
LODGEMENT DATE 2018-07-30
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 27
ENVIRONMENT IMPACT POTENTIAL 55
ENERGY CONSUMPTION CURRENT 640
ENERGY CONSUMPTION POTENTIAL 322
CO2 EMISSIONS CURRENT 7.0
CO2 EMISS CURR PER FLOOR AREA 108
CO2 EMISSIONS POTENTIAL 3.5
LIGHTING COST CURRENT 48
LIGHTING COST POTENTIAL 53
HEATING COST CURRENT 1810
HEATING COST POTENTIAL 377
HOT WATER COST CURRENT 302
HOT WATER COST POTENTIAL 146
TOTAL FLOOR AREA 64
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL 1
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS No thermostatic control of room temperature
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 2
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, standard tariff
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, insulated (assumed)
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Room heaters, electric
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION No thermostatic control of room temperature
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR no corridor
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.96
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 6 Balham Villas, Granby Street
LOCAL AUTHORITY LABEL West Suffolk
CONSTITUENCY LABEL West Suffolk
POSTTOWN NEWMARKET
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2018-07-30 21:37:01
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 14
LOW ENERGY FIXED LIGHT COUNT 14
UPRN 200001364385
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2018.csv
COUNTRY England
REGION E12000006
Address display
Nation ew