Energy Performance Certificate

Corner Pin, Bridge End, Great Bardfield, CM7 4TB

EPC Report

Energy rating

Current: 25 F | Potential: 81 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 25 F Current: 25 F 81 B Potential: 81 B

Environmental impact (CO₂)

Current: 17 | Potential: 46
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 17 Current: 17 46 Potential: 46
Field Value
LMK KEY 8200-9275-1129-4797-0433
ADDRESS1 Corner Pin
ADDRESS2 Bridge End
ADDRESS3 Great Bardfield
POSTCODE CM7 4TB
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 25
POTENTIAL ENERGY EFFICIENCY 81
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2017-04-13
LOCAL AUTHORITY E07000067
CONSTITUENCY E14001121
COUNTY
LODGEMENT DATE 2017-04-13
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 17
ENVIRONMENT IMPACT POTENTIAL 46
ENERGY CONSUMPTION CURRENT 806
ENERGY CONSUMPTION POTENTIAL 380
CO2 EMISSIONS CURRENT 12
CO2 EMISS CURR PER FLOOR AREA 119
CO2 EMISSIONS POTENTIAL 5.5
LIGHTING COST CURRENT 137
LIGHTING COST POTENTIAL 69
HEATING COST CURRENT 1830
HEATING COST POTENTIAL 1229
HOT WATER COST CURRENT 278
HOT WATER COST POTENTIAL 101
TOTAL FLOOR AREA 97
ENERGY TARIFF Unknown
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 75
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 0
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Partial double glazing
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Timber frame, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, wood logs
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 200 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION No low energy lighting
LIGHTING ENERGY EFF Very Poor
LIGHTING ENV EFF Very Poor
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.22
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS Corner Pin, Bridge End, Great Bardfield
LOCAL AUTHORITY LABEL Braintree
CONSTITUENCY LABEL Braintree
POSTTOWN BRAINTREE
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2017-04-13 13:44:40
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 19
LOW ENERGY FIXED LIGHT COUNT 0
UPRN 10006915320
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2017.csv
COUNTRY England
REGION E12000006
Address display
Nation ew