Energy Performance Certificate

5 Church Road West, L4 5UE

EPC Report

Energy rating

Current: 64 D | Potential: 80 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 64 D Current: 64 D 80 C Potential: 80 C

Environmental impact (CO₂)

Current: 59 | Potential: 76
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 59 Current: 59 76 Potential: 76
Field Value
LMK KEY 8200-1518-0522-0509-3353
ADDRESS1 5 Church Road West
ADDRESS2
ADDRESS3
POSTCODE L4 5UE
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 64
POTENTIAL ENERGY EFFICIENCY 80
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2025-07-09
LOCAL AUTHORITY E08000012
CONSTITUENCY E14001339
COUNTY
LODGEMENT DATE 2025-07-09
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 59
ENVIRONMENT IMPACT POTENTIAL 76
ENERGY CONSUMPTION CURRENT 225
ENERGY CONSUMPTION POTENTIAL 126
CO2 EMISSIONS CURRENT 4.3
CO2 EMISS CURR PER FLOOR AREA 41
CO2 EMISSIONS POTENTIAL 2.5
LIGHTING COST CURRENT 59
LIGHTING COST POTENTIAL 60
HEATING COST CURRENT 1261
HEATING COST POTENTIAL 732
HOT WATER COST CURRENT 211
HOT WATER COST POTENTIAL 212
TOTAL FLOOR AREA 104
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 17
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 7
NUMBER HEATED ROOMS 7
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Some double glazing
WINDOWS ENERGY EFF Very Poor
WINDOWS ENV EFF Very Poor
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, insulated (assumed)
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Excellent lighting efficiency
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.75
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 5 Church Road West
LOCAL AUTHORITY LABEL Liverpool
CONSTITUENCY LABEL Liverpool Walton
POSTTOWN LIVERPOOL
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2025-07-09 20:52:29
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 21
LOW ENERGY FIXED LIGHT COUNT 21
UPRN 38032988
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2025.csv
COUNTRY England
REGION E12000002
Address display
Nation ew