Energy Performance Certificate

8, Harrison Road, B97 5BP

EPC Report

Energy rating

Current: 58 D | Potential: 78 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 58 D Current: 58 D 78 C Potential: 78 C

Environmental impact (CO₂)

Current: 52 | Potential: 75
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 52 Current: 52 75 Potential: 75
Field Value
LMK KEY 8197-7029-1399-7744-4902
ADDRESS1 8, Harrison Road
ADDRESS2
ADDRESS3
POSTCODE B97 5BP
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 58
POTENTIAL ENERGY EFFICIENCY 78
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2013-11-04
LOCAL AUTHORITY E07000236
CONSTITUENCY E14001441
COUNTY
LODGEMENT DATE 2013-11-28
TRANSACTION TYPE Non-marketed sale
ENVIRONMENT IMPACT CURRENT 52
ENVIRONMENT IMPACT POTENTIAL 75
ENERGY CONSUMPTION CURRENT 242
ENERGY CONSUMPTION POTENTIAL 124
CO2 EMISSIONS CURRENT 6.4
CO2 EMISS CURR PER FLOOR AREA 47
CO2 EMISSIONS POTENTIAL 3.3
LIGHTING COST CURRENT 107
LIGHTING COST POTENTIAL 67
HEATING COST CURRENT 1119
HEATING COST POTENTIAL 753
HOT WATER COST CURRENT 104
HOT WATER COST POTENTIAL 105
TOTAL FLOOR AREA 137
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, TRVs and boiler energy manager
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 3
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 40
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 12 mm loft insulation
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, TRVs and boiler energy manager
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 40% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.42
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 8, Harrison Road
LOCAL AUTHORITY LABEL Redditch
CONSTITUENCY LABEL Redditch
POSTTOWN REDDITCH
CONSTRUCTION AGE BAND England and Wales: 1967-1975
LODGEMENT DATETIME 2013-11-28 23:00:50
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 25
LOW ENERGY FIXED LIGHT COUNT 10
UPRN 100120622528
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2013.csv
COUNTRY England
REGION E12000005
Address display
Nation ew